background image

Product Data Document

420DS-12A

October 1, 2007 - Page 4

Integrated Pump Control 

SCADA RTU

Website:  www.EmersonProcess.com/Remote

Remote Automation Solutions

The initial configuration setup is presented in a step-

by-step procedure using a question and answer for-

mat.  Once familiar with the procedures, individual 

configuration pages can easily be accessed rather 

than using the Q & A format.

A station overview display is also provided to show 

pump run status, local/remote operation, and instan-

taneous values of pressure, flow and level.  

Setup and configuration may also be performed 

from the integral display/keypad on the ControlWave 

PLC/RTU SCADA package or via the SCADA 

system host HMI. All configuration parameters are 

made available to OPC servers for compatibility with 

our OpenEnterprise SCADA software as well as 

third party SCADA software packages.

The configuration pages allow you to set the com

-

munication address and parameters, select station 

control mode parameters, enter setpoints and alarm 

limits, modify zero and span for analog inputs, add 

permissives and interlocks, and perform pump 

startups.

Q & A Configuration

Configuration Page

I/O Configuration

Loop Control Page

Summary of Contents for Control Wave SCADA RTU

Page 1: ...o maintain level pressure and or flow Some sites may also have the need to control chemical feed measure rain level and detect intrusion events All of these are pre programmed and available for use to customize for the specific site When the application requires modifications or addi tions to the standard program Bristol ControlWave Designer allows unlimited customization by your engineering staff...

Page 2: ... 2 tank level DI Intrusion or Motion Digital outputs Pump 1 2 start Pump 1 2 Stop Analog inputs Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level Analog outputs VFD speed control Chemical feed pump Counter inputs Station flow Rain gauge Triplex Booster or Lift Station Digital inputs Pump 1 2 3 status Pump 1 2 3 Remote Local 2 tank level DI Intrusion or Mot...

Page 3: ...icantly benefiting radio and cellular network architectures Daily Archive Stores 35 days of time stamped minimums maxi mums averages and totals Hourly Archive Stores hourly time stamped minimums maximums averages and totals Trend Archive The Trend Archive stores instantaneous values at a fixed period from one minute to sixty minutes Setup and Configuration As mentioned earlier the ControlWave pump...

Page 4: ... taneous values of pressure flow and level Setup and configuration may also be performed from the integral display keypad on the ControlWave PLC RTU SCADA package or via the SCADA system host HMI All configuration parameters are made available to OPC servers for compatibility with our OpenEnterprise SCADA software as well as third party SCADA software packages The configuration pages allow you to ...

Page 5: ...nsducers Tank and wet well level measurement 5 to 700 feet 05 to 1 full scale accuracy Non fouling diaphragm options for lift station applications 4 20 mA or 0 5 V output AquaSensors Water Quality Instruments The AquaSensors DataStick provides a cost ef fective plug and play analytical measurement sys tem for continuous use in industrial environments DataStick communicates with ControlWave via a p...

Page 6: ...prove the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user OpenEnterprise SCADA Host T...

Reviews: