background image

2

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver
One stepladder
One 1/4” blade screwdriver
One wire stripper
Three wire connectors (supplied).

MATERIALS

Wiring outlet box and box connectors must
be of type required by the local code. The
minimum wire would be a 3-conductor (2-
wire with ground) of the following size:

Before assembly your ceiling fan, refer to
section on proper method of wiring your
fan (page 7). If you feel you do not have
enough wiring knowledge or experience,
have your fan installed by a licensed
electrician.

WARNING

!

Do not install or use fan if any part is
damaged or missing. Call Toll-Free:

1-800-654-3545

WARNING

!

This product is designed to use only
those parts supplied with this product
and/or any accessories designated
specifically for use with this product by
Emerson Electric Co. Substitution of
parts or accessories not designated for
use with this product by Emerson
Electric Co. could result in personal
injury or property damage.

WARNING

!

Installed Wire Length Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each
step is completed, place a check mark in the box. This will insure that all steps
have been completed and will be helpful in finding your place should you be
interrupted.

1. Check to see that you have received

the following parts:

NOTE: If you are uncertain of part
description, refer to exploded view
illustration.

a. Fan motor assembly

b. One switch housing assembly
c. Five fan blades
d. One ceiling cover
e. Five blade flanges
f. One hanger ball/downrod assembly
g. One hanger bracket

h. One coupling cover

i. One loose parts bag containing:

1. Sixteen 3/16-24 x 1/2”

slotted Phillips blade screws

2. Sixteen blade washers
3. Eleven 1/4-20 x 1/2” Phillips oval

head flange screws

4. One wood pendant
5. One coupling
6. Three wire connectors
7. Two threaded studs
8. Two knurled knobs
9. Two lockwashers

10. One clevis pin
11. One hairpin clip

COUPLING
COVER

CEILING
COVER

BLADE
FLANGES

SWITCH CUP
ASSEMBLY

HANGER
BRACKET

HANGER BALL/
DOWNROD
ASSEMBLY

LOOSE
PARTS
BAG

FAN MOTOR
ASSEMBLY

FAN
BLADES

BP7287 60" DESIGNER FAN  3/10/05  10:42 AM  Page 2

Summary of Contents for CF760AB00

Page 1: ...or Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan...

Page 2: ... result in personal injury or property damage WARNING Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted 1 Check to se...

Page 3: ...vis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The...

Page 4: ...h housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three screws Figure 6 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan fal...

Page 5: ...unded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electrical shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not accep...

Page 6: ...G FLOOR Figure 9 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 11 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 10 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER B...

Page 7: ...ed GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 12 NOTE CEILING COVER OMITTED FOR CLARITY NOTE If you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring 2 Securely connect the fan motor white wire to the suppl...

Page 8: ...ws THREE SPEED 1st Pull HIGH 2nd Pull Medium 3rd Pull Low 4th Pull OFF SPEED CONTROL SWITCH REVERSIBLE SWITCH Accessories Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use w...

Page 9: ...e caused by solid 5 Some fan motors are sensitive state variable speed control to signals from Solid State variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 6 Screws holding blades to 6 Tighten screws securely flanges are loose 3 Fan wobbles 1 Setscrew in motor coupling is 1 Tighten both setscrews securely excessively loose in the m...

Page 10: ...ve been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 BP7287 60 DESIGNER FAN 3 10 05 10 42 AM Page 10 ...

Page 11: ... 2 16 Lockwasher External Tooth 8 2 17 Knurled Knob 8 32 2 18 Coupling 1 19 Blade Washer 16 5 Ceiling Canopy 1 761620 3 761620 29 761620 25 761620 33 761620 30 761620 26 761620 11 Wiring Harness 1 762847 762847 1 762847 2 762847 762847 762847 762847 2 12 Switch Housing 1 761919 761919 16 761919 9 761919 21 761919 17 761919 3 761919 5 13 Blade Set set of 5 762845 762845 1 762845 2 762845 3 762845 2...

Page 12: ...ponsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any de...

Reviews: