background image

5. Secure the ceiling cover in place by sliding

lockwashers over the threaded studs and installing the
two knurled knobs (supplied). (Figure 8). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling and the hole in the ceiling
cover is clear of the downrod. Your fan is now wired to
be turned on and off from the fan switch.

6. Cut the 3-speed switch pull chain to a desired

length (optional). Connect the wood pendant
(supplied) to the 3-speed switch pull chain by
sliding the wooden pendant (small hole first) onto
the pull chain. Attach the chain coupling to the end
of the chain and allow the wooden pendant to fall
down over the coupling.

NOTE: If you are using an Emerson light fixture
with your fan, remove the three screws securing
the switch housing cover to the switch housing
and remove the cover. Remove the screw plug
from the bottom of the switch housing cover and
install the light in accordance with the light kit
Owner's Manual.

2.Connect the fan motor white wire to the supply

white (neutral) wire using a wire connector
(supplied) (Figure 7). Connect the fan motor black
wire and blue wire to the supply black (hot) wire
using a wire connector (supplied) (Figure 7). Your
fan is now wired to be turned on and off from the
fan switch. After connections have been made, turn
leads upward and carefully push leads into the
outlet box, with the white and green leads on one
side of the outlet box and the black and blue leads
on the other side of the outlet box.

3. Screw the two threaded studs (supplied) into the

tapped holes in the hanger bracket.

4. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 8).

CEILING COVER

THREADED STUD

KNURLED KNOB

LOCKWASHERS (2)

Figure 8

1.Restore electrical power to the outlet box by turning

the electricity on at the main fuse box.

2.Check the operation of the fan by gently pulling on

the pull chain switch.

3.All fans are shipped from the factory with the

reversing switch positioned to circulate air
downward. If airflow is desired in opposite direction,
turn your fan off and wait for the blades to stop
turning, then slide the reversing switch to opposite
position, and turn fan on again. The fan blades will
turn the opposite direction and reverse the airflow.

Your fan model is equipped with a 4-position, 3-speed
pull chain switch. The operating sequence is as
follows:

Using Your Ceiling Fan

SPEED
CONTROL
SWITCH

REVERSIBLE
SWITCH

THREE-SPEED
1st Pull — High
2nd Pull — Medium
3rd Pull — Low
4th Pull — Off

6

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

To reduce the risk of fire or electrical shock, do not
use this fan with any solid-state speed control
device.

WARNING

!

Summary of Contents for CF742PFOB

Page 1: ...to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered Th...

Page 2: ...upporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan b...

Page 3: ... blades c One ceiling cover d Five blade flanges e One hanger ball downrod assembly f One hanger bracket g One loose parts bag containing 1 Sixteen 3 16 24 x 1 2 screws 2 Eleven 1 4 20 x 7 16 blade flange screws 3 One pull chain pendant 4 One pull chain coupling 5 Three wire connectors 6 One clevis pin 7 One hairpin clip 8 Two threaded studs 9 Two lockwashers 10 Two knurled knobs NOTE Place the pa...

Page 4: ...IS PIN HAIRPIN CLIP CLEVIS PIN HANGER BALL DOWNROD ASSEMBLY SETSCREW SETSCREW Figure 1 Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this ...

Page 5: ... BLACK AND BLUE FAN WIRES Figure 7 NOTE CEILING COVER OMITTED FOR CLARITY 5 The fan must be hung with at least 7 of clearance from floor to blades Figure 4 WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws...

Page 6: ...e black and blue leads on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 8 CEILING COVER THREADED STUD KNURLED KNOB LOCKWASHERS 2 Figure 8 1 Restore electrical power to the outlet box by turning the elect...

Page 7: ... fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 6 Fan blades out of balan...

Page 8: ...Knob 2 Pull Chain Pendant Pull Chain Coupling Owners Manual BP7178 5 BP7178 5 6 6 6 4 5 6 3 6 2 1 1 1 6 6 6 7 6 6 Part No F40BP71780005 Form No BP7178 5 Printed in Taiwan 09 99 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER T...