background image

Removal Of The

Light Fixture

NOTE: In some instances it may be desirable to
install the ceiling fan without the light fixture. If
this is the case, proceed as follows. (You may
want to keep the light fixture for possible future
use.)

1.

Remove and retain the three screws securing the
light fixture to the switch housing (Fixture 14).
Remove  and retain two wire connectors and
disconnect the light fixture from the switch
housing. 

2.

Use the wire connectors to securely cap the each
of the two wires in the switch housing (Figure 15). 

3.

Position the switch housing cover (supplied) on the
switch housing so that the notch in the cover
clears the reversing switch. Install the three screws
to secure the cover.

8

SWITCH
HOUSING

LIGHT 
FIXTURE

SCREW (3)

Figure 14

SCREW (3)

SWITCH 
HOUSING COVER

SWITCH 
HOUSING

DISCONNECT TWO
WIRES FROM LIGHT
FIXTURE AND 
SECURELY CAP WITH
WIRE CONNECTORS

Figure 15

RETAINING
CLIP

SQUEEZE
RETAINING
CLIPS
TOGETHER 
AND SLIDE
ON GLASS
SHADE

GLASS
SHADE

13W E26 MEDIUM BASE 
BULB CFL (3 or 4)

Figure 13

2.

Mount one blade assembly to the motor hub by
mating the alignment post (Figure 11) of the flange
with one of the alignment slots in the motor hub
(Figure 12). Then tighten the two captive screws in
the flange to secure the flange to the motor hub.
Repeat this procedure for the other four blade
assemblies. Make sure all screws are tightened.

Installing The Glass Shades

and Light Bulbs

1.

To install the glass shade, squeeze the retaining
clips towards the bulb socket and slide on the
glass shade (Figure 13). The spring clips will seat
the shade and secure it in place. 

2.

Install a 13W E26 medium base bulb CFL in each
of the light fitter sockets.

3.

To remove the shade, first remove the light bulb
from the socket, then simply pull the shade off
using a twisting motion.

U.L. Model No.: 42-ANT/52-ANT

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

CAPTIVE
SCREW (2)

BLADE FLANGE

ALIGNMENT
SLOT

MOTOR HUB

Figure 12

Summary of Contents for CF710AB02

Page 1: ...S PRO SERIES II Ceiling Fan Owner s Manual Net Weight 19 8 Lbs Net Weight 15 0 Lbs 50 PRO SERIES II Model No CF711AB02 CF711ORS02 CF711AW02 CF711PB02 CF711BS02 CF711WB02 CF711CK02 CF711WW02 CF711ORB02 42 PRO SERIES II Model No CF710AB02 CF710AW02 CF710BS02 CF710ORB02 CF710PB02 CF710WW02 CF711 shown ...

Page 2: ... Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades ...

Page 3: ...h step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or u...

Page 4: ...d to be installed either in the standard manner or in the close to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case sho...

Page 5: ...nd or outlet box are not securely attached the fan could wobble or fall WARNING Hanging The Ceiling Fan Standard Method Using Hanger Ball Downrod 1 Carefully lift the fan assembly and seat the hanger ball in the hanger bracket Figure 7 The tab on the hanger bracket must seat in the groove in the hanger ball NOTE The hanger bracket must be mounted flush with the ceiling in order for the ceiling cov...

Page 6: ...g off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor...

Page 7: ... blade Figure 11 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 9 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of t...

Page 8: ...P SQUEEZE RETAINING CLIPS TOGETHER AND SLIDE ON GLASS SHADE GLASS SHADE 13W E26 MEDIUM BASE BULB CFL 3 or 4 Figure 13 2 Mount one blade assembly to the motor hub by mating the alignment post Figure 11 of the flange with one of the alignment slots in the motor hub Figure 12 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other fo...

Page 9: ...flanges to motor hub 2 Check to make sure the screws which attach the fan are loose flanges to the motor hub are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid state variable 4 ...

Page 10: ...of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your ceiling fan while in your possession or Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voide...

Page 11: ...rding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 U L Model No 42 ANT 52 ANT ...

Page 12: ...asher Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket Owner s Manual BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 Repair Parts Listing Form No BP7258 8 Part No F40BP72580008 Printed in China 06 10 Air Comfort Products DIVISION OF Emerson Electric Co 8100 W Florissant St Louis MO 63136 42 PRO SERIES II Model Numbers Key No Description CF710AB02 CF7...