background image

Installing The Hanger

Ball/Downrod Assembly

(For Standard Mounting)

1.

Pass the 42” motor leads through the opening in
the ceiling cover. Be sure the cover is oriented
correctly.

2.

Separate, untwist and unkink the three motor
leads. Route the motor leads through the hanger
ball/downrod assembly.

3.

Loosen the two setscrews in the motor coupling.
Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 1). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Be sure to
push the straight leg of the hairpin clip through the
hole near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on
the hanger ball to make sure the clevis pin is
properly installed.

4.

While pulling up on the hanger ball, securely
tighten the two setscrews in the motor coupling
(Figure 1).

NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.

5.

The fan comes with blue, black and white leads that
are 42” long. Measure up approximately
6 to 9-inches above top of hanger ball/downrod
assembly. Cut off excess leads and strip back
insulation 1/2-inch from end of leads.

4

HANGER 
BALL/DOWNROD 
ASSEMBLY

CEILING 
COVER

SETSCREW

CLEVIS
PIN

HAIRPIN
CLIP

DECORATIVE
CAP

SETSCREW

MOTOR COUPLING

Figure 1

IMPORTANT

Your ceiling fan is designed to be installed
either in the standard manner, or in the
close-to-the-ceiling manner. Using the
standard method, the hanger ball/downrod
assembly will suspend the fan several inches
below the ceiling cover. Using the
close-to-the-ceiling method, the ceiling cover
installs directly on the fan motor housing,
thus mounting the fan 3-1/2 inches closer to
the ceiling than the standard method. In no
case should the fan blades be lower than
seven feet above the floor. Depending on
your desired mounting method, proceed to
“INSTALLING HANGER BALL/DOWNROD
ASSEMBLY” for standard mounting, or to
“INSTALLING CEILING COVER ON FAN
MOTOR HOUSING” for close-to-the-ceiling
mounting.

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.

WARNING

!

Installing The Ceiling Cover

On The Fan Motor Housing

(For Close-to-the-Ceiling Mounting)

1.

Remove and retain three screws from the top of
the motor housing (Figure 2A).

2.

Position the rubber gasket (supplied in parts bag)
on the motor housing (small holes in gasket
centered over the screw holes in the housing)
(Figure 2B).

3.

Gently pry the decorative cap (Figure 1) from the
ceiling cover. Align the holes in the ceiling cover
with the holes in the motor housing and secure
using the three screws (Figure 3).

4.

The fan comes with blue, black and white leads
that are 42” long. Measure up approximately 6 to
9-inches above the motor coupling. Cut off excess
leads and strip back insulation 1/2-inch from ends
of leads. 

REMOVE SCREWS (3)

INSTALL GASKET

Figure 2A

Figure 2B

SCREW (3)

RUBBER
GASKET

Figure 3

U.L. Model No.: 42-ANT/52-ANT

Summary of Contents for CF710AB02

Page 1: ...S PRO SERIES II Ceiling Fan Owner s Manual Net Weight 19 8 Lbs Net Weight 15 0 Lbs 50 PRO SERIES II Model No CF711AB02 CF711ORS02 CF711AW02 CF711PB02 CF711BS02 CF711WB02 CF711CK02 CF711WW02 CF711ORB02 42 PRO SERIES II Model No CF710AB02 CF710AW02 CF710BS02 CF710ORB02 CF710PB02 CF710WW02 CF711 shown ...

Page 2: ... Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades ...

Page 3: ...h step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or u...

Page 4: ...d to be installed either in the standard manner or in the close to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case sho...

Page 5: ...nd or outlet box are not securely attached the fan could wobble or fall WARNING Hanging The Ceiling Fan Standard Method Using Hanger Ball Downrod 1 Carefully lift the fan assembly and seat the hanger ball in the hanger bracket Figure 7 The tab on the hanger bracket must seat in the groove in the hanger ball NOTE The hanger bracket must be mounted flush with the ceiling in order for the ceiling cov...

Page 6: ...g off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor...

Page 7: ... blade Figure 11 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 9 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of t...

Page 8: ...P SQUEEZE RETAINING CLIPS TOGETHER AND SLIDE ON GLASS SHADE GLASS SHADE 13W E26 MEDIUM BASE BULB CFL 3 or 4 Figure 13 2 Mount one blade assembly to the motor hub by mating the alignment post Figure 11 of the flange with one of the alignment slots in the motor hub Figure 12 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other fo...

Page 9: ...flanges to motor hub 2 Check to make sure the screws which attach the fan are loose flanges to the motor hub are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid state variable 4 ...

Page 10: ...of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your ceiling fan while in your possession or Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voide...

Page 11: ...rding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 U L Model No 42 ANT 52 ANT ...

Page 12: ...asher Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket Owner s Manual BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 Repair Parts Listing Form No BP7258 8 Part No F40BP72580008 Printed in China 06 10 Air Comfort Products DIVISION OF Emerson Electric Co 8100 W Florissant St Louis MO 63136 42 PRO SERIES II Model Numbers Key No Description CF710AB02 CF7...