background image

7

OUTLET BOX

BLACK SUPPLY WIRE

BLACK/WHITE RECEIVER WIRE

BLACK FAN WIRE

BLUE FAN WIRE

BLUE RECEIVER 
WIRE

YELLOW RECEIVER 
WIRE 

DO NOT USE

CEILING COVER

WHITE RECEIVER WIRE

WHITE FAN WIRE

WIRE CONNECTOR

RECEIVER

WHITE SUPPLY
WIRE

SUPPLY GROUND
WIRE (GREEN OR 
BARE)

HANGER BALL
GROUND WIRE
(GREEN)

HANGER BRACKET
GROUND WIRE
(GREEN)

HANGER BRACKET

BLACK RECEIVER WIRE

OPEN 

PORTION OF 

RECEIVER 

HERE

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse or circuit breaker box
before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be
properly grounded as a precaution against possible
electrical shock.

WARNING

!

Figure 12

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician. 

CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan and light kit or receiver.

1.

Pull the wire leads, coming from the end of the
downrod, and the supply wires through the open
side of the hanger bracket. (Figure 12).

2.

Position the SW105 Receiver (supplied) in the ceil-
ing cover so that the flat side of the receiver faces
up and the open portion of the receiver is to the
right, as shown in Figure 12.

3.

Using wire connectors (supplied), make wiring con-
nections as follows (Figure 12 and 13):

a.

Connect the white fan wire and the white supply
wire to the white receiver wire (AC IN/
MOTOR N).

b.

Connect the black fan wire to the black receiver
wire (TO MOTOR L).

c.

Connect the black supply wire to the black/white
receiver wire (AC IN L).

d.

Cut off the ends of the blue and yellow receiver
wires and strip back insulation 1/2-inch from the
ends of the wires.

e.

Connect the blue fan wire to the blue receiver
wire (BOTTOM LIGHT).

f.

Connect the green ground wires from the hang-
er bracket and the hanger ball to the supply
ground wire (bare or green).

NOTE: Do not use capped yellow wire.

How to Wire Your Ceiling Fan

U.L. Model No.:  CF3000

Summary of Contents for CF3000BS00 ORIGAMI

Page 1: ... THESE INSTRUCTIONS Model Numbers ORIGAMI Part No F40BP73490000 Form No BP7349 U L Model No CF3000 Net Weight 25 0 Lbs Damp Location Ceiling Fan Owner s Manual CF3000BS00 Brushed Steel CF3000ORB00 Oil Rubbed Bronze ...

Page 2: ...t with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician CAUTION The halogen bulb operates at high internal pressure and high surface temperatures and could shatter unexpectedly The halogen bulb generates UV ultraviolet radiation that may cause ski...

Page 3: ...o 1 1 4 threaded studs 3 4 Two knurled knobs 5 Two lockwashers 6 Five wire connectors 7 One hairpin clip 8 One clevis pin 9 Twenty one 10 24 x 15mm flat head screws 10 Four 8 32 x 10mm pan head screws 11 Four 8 32 x 12mm pan head screws 12 One balancing kit NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local r...

Page 4: ...g the setscrew wrench supplied NOTE The setscrew must be properly installed as described above or fan wobble could result 6 Slide the switch housing cover over the downrod and position the cover onto the upper housing Install the three 8 32 x 10mm pan head screws supplied Figure 3 7 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the to...

Page 5: ... two rods of the preassembled fan blade into the two holes of the housing center band Install the four 10 24 x 15mm flat head screws 2 pre rod 4 per blade assembly supplied securing the fan blade to the housing Figure 6 Install the remaining four fan blades using the same procedure 12 Connect the switch housing blue wire single pin connector to the black wire single pin connector from the light ki...

Page 6: ...ING Figure 9 The fan must be hung with at least 7 of clearance from floor to blades Figure 9 WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 10 2 Carefully lift the fan and seat the hanger ball down rod assembly on the hanger bracket that was just attached to the outlet box Figure 11 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figu...

Page 7: ...connect the electrical supply circuit before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 12 2 Position the SW105 Receiver supplied in the ceil ing cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right as shown in Figur...

Page 8: ...hite wires into one side of the outlet box push the black blue and yellow wires into the other side of the outlet box Figure 13 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING 6 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 15 7...

Page 9: ...ION To avoid risk of burns or other injury assure power is off before attempting to install or replace the 75 watt max mini candelabra E11 base bulb CAUTION To not touch 75 watt max mini candelabra E11 base bulb with bare hands Fingerprints may result in shorter bulb life Remove fingerprints with alcohol Light Kit Installation 1 Place the switch cover onto the light kit assembly aligning the three...

Page 10: ... is supplied with a white ivory or almond color cover Choose the style that best suits your needs and snap the cover onto the wall control Figure 20 12V BATTERY WALL CONTROL COVER SW114 WALL CONTROL HI HI MED MED LOW LOW FAN OFF REV REV LIGHT Figure 20 Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker ...

Page 11: ...e while the button is held down When the light is at the desired brightness release the button 5 To turn the light on or off press and release the LIGHT button The light will turn on at the light level previously set See Step 4 Red indicator light turns on when any button is pressed If the light does not come on replace the battery Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Perio...

Page 12: ...orrect the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits fo...

Page 13: ... Make sure main power is turned off 4 Loose screws in motor housing 4 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is not tightened 1 Raise coupling cover and tighten setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly 2 Tighten the setscrew in the hanger ball downrod assembly is loose 3 Screws s...

Page 14: ...14 Repair Parts 6 1 11 10 4 19 7 8 HI HI MED MED LOW LOW FAN OFF REV REV LIGHT 3 2 16 17 13 5 18 21 30 12 29 22 20 27 14 25 26 28 9 15 23 24 31 U L Model No CF3000 ...

Page 15: ...2 763492 20 Capacitor Aux 1 763493 763493 21 Hub Motor 760601 760601 22 Center Housing 1 763425 BS 763425 ORB 23 Mounting Hub Flange 1 763424 763424 24 Lower Housing 1 763435 BS 763435 ORB 25 Light Kit Assembly 1 763440 763440 26 Bulb Halogen 75 Watt Mini Candelabra 762737 762737 27 Glass Lower 1 763437 763437 28 Cover Decorative Light 1 763438 BS 763438 ORB 29 Blade Assembly 5 per set 763426 1 76...

Page 16: ...ion charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by per...

Reviews: