background image

Part No. F40BP73750002

Printed in China  09/12

Form No. BP7375-2

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant • St. Louis, MO 63136

U.L. Model No.: CF205

Emerson Air Comfort Ceiling Fan Limited Warranty

What The Limited Warranty Covers:

This limited warranty is offered by Air Comfort Products division of Emerson Electric Co. (

"Emerson" "we"

or 

"us"

) located at the address stated below to the original retail pur-

chaser (

"you"

or 

"your"

) of an Emerson Air Comfort Ceiling Fan product (

"Emerson Ceiling Fan"

) and covers the motor and the other components and accessories of the

Emerson Ceiling Fan against all defects in workmanship and materials.

What The Period Of Coverage Is:

This limited warranty will cover the Emerson Ceiling Fan motor for the expected lifetime of your Emerson Ceiling Fan (when operated in accordance with your Owner's Manual
or other instructions provided by Emerson to you with the Emerson Ceiling Fan). All other components and accessories of the Emerson Ceiling Fan are covered by this limited
warranty for a period of one (1) year from its date of original retail purchase. ANY IMPLIED WARRANTY, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS AVAILABLE TO YOU UNDER THE LAWS OF YOUR STATE OR PROVINCE SHALL COVER THE
MOTOR FOR THE EXPECTED LIFETIME OF THE MOTOR (SUBJECT TO PROPER USE), AND FOR ONE YEAR WITH RESPECT TO COMPONENTS AND ACCESSORIES.

No Other Express or Implied Warranty Applies:

THE LIMITED WARRANTIES PROVIDED ABOVE ARE THE SOLE AND EXCLUSIVE WARRANTIES PROVIDED BY EMERSON TO YOU FOR YOUR EMERSON CEILING FAN, AND
ARE IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED, WHETHER ARISING BY OPERATION OF LAW OR OTHERWISE, WHETHER OR NOT
THE PURPOSE HAS BEEN DISCLOSED AND WHETHER OR NOT THE EMERSON CEILING FAN HAS BEEN SPECIFICALLY DESIGNED OR MANUFACTURED FOR YOUR USE OR
PURPOSE. EMERSON HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE FOR COMPONENTS AND ACCESSORIES AS OF THE EXPIRATION OF THE ONE YEAR WARRANTY PERIOD FOR SUCH COMPONENTS
AND ACCESSORIES. IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR THE MOTOR PORTION OF THE EMERSON CEILING
FAN ARE LIKEWISE DISCLAIMED BY EMERSON AT SUCH TIME THAT THE EXPECTED LIFETIME OF THE EMERSON CEILING FAN UNDER NORMAL USAGE HAS BEEN
REACHED.  EXCLUSIONS OR LIMITATIONS OF IMPLIED WARRANTIES MAY VARY FROM STATE TO STATE AND PROVINCE TO PROVINCE SO THE ABOVE LIMITATIONS
MAY NOT APPLY TO YOU.

What We Will Do To Correct Problems:

If during the one (1) year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship, or if during the
expected lifetime of the Emerson Ceiling Fan (when used in accordance with the User Manual or other instructions) the motor is defective in materials or workmanship, you
must contact Emerson during the applicable warranty period. If the defect is covered by warranty, Emerson will repair or replace the defective motor, component or other
accessory at no charge to you. If repair of the motor, component or accessory is not practical or possible within a reasonable time and no replacement Emerson Ceiling Fan
can be provided, Emerson will refund to you the actual purchase price of your Emerson Ceiling Fan. We will ship the repaired or the replacement Emerson Ceiling Fan to you at
no charge, but you are responsible for all costs of removal and reinstallation of your Emerson Ceiling Fan.

How You Can Receive Warranty Service:

You must be the original retail purchaser and have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty. You can return your
Emerson Ceiling Fan to your place of purchase, or you can call Emerson Customer Service at 1-800-237-6511 to obtain a return authorization and service identification tag. In
order for us to confirm that your Emerson Ceiling Fan is still under warranty, please retain your receipt or other proof of purchase and have that information readily available
when returning your Emerson Ceiling Fan to your place of purchase, or upon calling Emerson Customer Service. If you call Emerson Customer Service, prior to your call please
be prepared to provide all model numbers shown on your Emerson Ceiling Fan. Once we have processed your return authorization request, we will provide you with a postage
paid return label which should be affixed to the Emerson Ceiling Fan package you ship to the address listed at the end of this limited warranty. The return label will be sent to
the mailing address you provide to us by phone. 

What Is Not Covered:

This limited warranty does not extend to and expressly excludes:

The glass globes and light bulbs of your Emerson Ceiling Fan, 

Loss or damage to the motor or any component or accessory caused by normal wear and tear, rather than due to defects in materials or workmanship,

Loss or damage resulting from conditions beyond our reasonable control, including without limitation, repairs not made at our factory or authorized service center, use of
parts or accessories not provided to you as part of this warranty by our factory or authorized service center, mishandling, unreasonable use, misuse, abuse, modifications
or other damage caused by you or a third party to your Emerson Ceiling Fan while not in our possession, 

Loss or damage resulting from improper installation, or other failure to comply with instructions in your Owner's Manual.

This limited warranty is deemed null and void upon the occurrence of either of the following events:

You cease to own the Emerson Ceiling Fan product, or

The Emerson Ceiling Fan is moved from its original point of installation.

This limited warranty is only valid within the 50 United States, the District of Columbia, and Canada. No other written or oral warranties apply, and no employee, agent, dealer
or other person is authorized to give any warranties on behalf of Air Comfort Products or Emerson Electric Co.

Limitation of Liability

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE TO YOU UNDER THIS LIMITED WARRANTY. TO THE EXTENT PERMITTED BY LAW, IN
NO EVENT SHALL EMERSON OR ANY EMERSON AUTHORIZED DEALER BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUD-
ING ANY ECONOMIC LOSS, WHETHER RESULTING FROM NONPERFORMANCE, USE, MISUSE OR INABILITY TO USE THE EMERSON CEILING FAN OR FOR THE NEGLIGENCE
OF EMERSON OR AN EMERSON AUTHORIZED DEALER. EMERSON SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT,
REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR
OTHERWISE), SHALL EMERSON'S OR ANY EMERSON AUTHORIZED AGENT'S LIABILITY TO YOU OR ANY INDIVIDUAL USING THE EMERSON CEILING FAN EXCEED THE
PRICE PAID BY THE ORIGINAL OWNER FOR THE EMERSON CEILING FAN. The term "consequential damages" shall include, but not be limited to, loss of anticipated profits,
business interruption, loss of use or revenue, cost of capital or loss or damage to property or equipment.

How State and Provincial Law Relates To The Warranty:

Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This limit-
ed warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

Summary of Contents for CF205BS01

Page 1: ...ling Fan Owner s Manual Model Numbers HIGHPOINTE Net Weight 22 1 Lbs CF205BS01 Brushed Nickel Finish with Opal Matte Glass and Dark Mahogany Blades CF205GES01 Golden Espresso with Sandstone Glass and Chocolate Blades CF205VS01 Vintage Steel with Vintage Cream Glass and Riverwash Honey Oak Blades ...

Page 2: ...mmended floor to fan blade clearance for a 9 foot ceiling The 6 downrod supplied must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan instal...

Page 3: ...not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or acces sories not designated for use with this product by Emerson Electric Co could result in personal injury or prop...

Page 4: ...inst possible electrical shock WARNING WARNING To reduce the risk of fire electrical shock or person al injury mount fan to outlet box marked Acceptable for Fan Support and use screws sup plied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING How to Assemb...

Page 5: ...it plate to the fan motor housing Figure 4 6 Carefully remove the fan assembly from the lower foam pad Turn the fan assembly over and posi tion it on the lower foam pad with the light kit plate resting on the pad so that the top of the motor faces up 7 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 5 Remove the pin from the d...

Page 6: ... NOTE If you installed the 6 downrod the three decorative rod assemblies and the rod support assembly will not be installed Disregard Steps 12 through 14 proceed to Step 15 11 Make sure the grommets are properly installed in the rod support assembly Then position the three screws in the rod support toward the top and slide the rod support over the downrod Figure 7 12 Using the decorative rod screw...

Page 7: ...hrough the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 16 The fan comes with blue black and white leads that are 80 long Before installing the fan mea sure up approximately 6 to 9 inches...

Page 8: ...ITY OUTLET BOX HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY 1 1 4 THREADED STUD 2 Figure 13 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 12 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 12 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the...

Page 9: ...nstalling the fan light kit or receiver 1 Position the supply wires to the left side of the out let box Figure 14 position the fan wires to the right side Partially insert the remote control receiv er flat side up until one end rests on the hanger ball as shown in Figure 14 NOTE Make all wiring connections using wire connectors supplied Make sure that all connec tions are tight including ground an...

Page 10: ...ing lock washers supplied over the threaded studs and installing the two knurled knobs supplied Figure 16 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling 7 Screw the two 50 watt mini candelabra base halo gen bulbs supplied into the light kit plate sockets Figure 17 Do not touch the glass bulb use the porcelain base to screw in the bulb or wear soft gloves...

Page 11: ...utters Unscrew the screws that is securing the socket plates to the light kit plate Pull socket wiring though light kit plate holes to completely disengage the light sock ets from light kit plate Figure 19 How to Disassemble Your Light Kit for Cover Plate Assembly Only LIGHT KIT PLATE BLACK WIRE BLUE WIRE FAN MOTOR HOUSING ASSEMBLY WHITE WIRES Figure 18 LIGHT KIT PLATE CUT LIGHT SOCKET WIRES CUT L...

Page 12: ...ol consists of hand held transmitter and a receiver which is mounted under the fan ceiling cover The remote control is designed to separately control your ceiling fan speed and light intensity There are four push buttons to set the fan speed and turn the fan off The light push button turns the light on and off and controls the light intensity The blue indicator light will illuminate while any butt...

Page 13: ... desire to use the bracket install it on a wall that is away from excess heat or humidity Operation of Remote Control IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your remote control has full control of your fan and light Figure 23 NOTE Prior to operation of the fan and light from the remote control set the fan speed...

Page 14: ...eeded When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING Trouble Shooting Remote Control Fan Light Fails to Operate Check that ...

Page 15: ...itch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Motor noise caused by solid state variable 5 Some fan motors are sensitive to signals from speed control solid state variable speed controls If solid state control is used and motor noise results choose an alternative control methods 6 Screws hol...

Page 16: ...ouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply...

Page 17: ...17 U L Model No CF205 Notes ...

Page 18: ...18 U L Model No CF205 Repair Parts 3 2 1 5 4 26 14 15 6 7 17 17 16 18 9 23 11 28 27 8 25 13 10 20 19 22 24 21 22 12 ...

Page 19: ...and lockwashers 4 13 Decorative Blade Nuts 9 763599 BS 763599 GES 763599 VS 14 Cover Ceiling 763592 BS 763592 GES 763592 VS 15 Support Assembly Rod 762709 BS 762709 GES 762709 VS 16 Rod Assembly Decorative 3 762710 BS 762710 GES 762710 VS 17 Screw Decorative Rod 6 762711 BS 762711 GES 762711 VS 18 Cover Coupling 762708 BS 762708 GES 762708 VS 19 Blade Set full set for one fan 763601 763601 1 76360...

Page 20: ...d have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your rece...

Reviews: