background image

10.

Carefully turn partially assembled fan
over and place on top of the
styrofoam, resting on switch cover
assembly.

7

11.

Remove the hanger ball by loosening
the setscrew in the hanger ball until
the ball falls freely down the downrod
(Figure 6). Remove the clevis pin from
the downrod, then remove the hanger
ball. Retain the pin and hanger ball for
reinstallation in Step 17.

12.

Separate, untwist and unkink the three
80” motor leads. Route the motor lead
wires through the downrod. Align the
clevis pin holes in the downrod with
the holes in the motor coupling. Install
the clevis pin and secure with the
hairpin clip (Figure 7). The clevis pin
must go through the holes in the motor
coupling and the holes in the downrod.
Be sure to push the straight leg of the
hairpin clip through the hole near the
end of the clevis pin until the curved
portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be

PIN

HANGER
BALL

SETSCREW

DOWNROD

Figure 6

Model No.: CF3600

SWITCH COVER 
ASSEMBLY

SWITCH COVER 
CONNECTOR

MOTOR ASSEMBLY 
CONNECTOR

SWITCH CHAIN 
BUSHING

Figure 5

HAIRPIN 
CLIP

CLEVIS PIN

MOTOR
COUPLING

5/16-18 x 1/4" 
SETSCREW

Figure 7

properly installed to prevent the clevis
pin from working loose. Pull on the
downrod to make sure the clevis pin is
properly installed.

13.

Install the 5/16-18 x 1/4” setscrew into
the threaded hole on the motor
coupling.

14.

While pulling up on the downrod,
securely tighten the 5/16-18 x 1/4”
setscrew (supplied) in the motor
coupling using the 3/16” hex wrench
(supplied) (Figure 7).

NOTE: The setscrew must be properly
installed as described above, or fan
wobble could result.

15.

Carefully place the motor housing
cover over the downrod the guide it
over the motor housing assembly.
Align the three mounting holes with the
corresponding threaded holes on top
of the motor. Install three #8-32 x 1/4”
pan head screws into the holes to
secure the motor cover (Figure 8).

It is critical that the clevis pin in the motor
coupling is properly installed and the
setscrew securely tightened. Failure to
verify that the pin and setscrew are
properly installed (as shown in Figure 4)
could result in the fan falling.

!

WARNING

BP7384 Camden, CF3600  3/12/09  12:37 PM  Page 7

Summary of Contents for CAMDEN CF3600AP

Page 1: ...l No CF3600 READ AND SAVE THESE INSTRUCTIONS Net Weight 15 9 Lbs CAMDEN 52 Damp Location Ceiling Fan Owner s Manual CF3600AP Antique Pewter CF3600ORH Oil Rubbed Bronze with Highlights Model Numbers BP7384 Camden CF3600 3 12 09 12 37 PM Page 1 ...

Page 2: ...only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ce...

Page 3: ...nce have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE If you are uncertain of part description refer to exploded view il...

Page 4: ...carefully on the styrofoam for blade assembly A FAN MOTOR ASSEMBLY I HANGER BRACKET K LOOSE PARTS BAG C COUPLING COVER D CEILING COVER B MOTOR COVER J HANGER BALL DOWNROD ASSEMBLY H SWITCH COVER PLATE G BLADE MEDALLION 4 F BLADE FLANGE 4 E SWITCH ADAPTER PLATE NOTE Place the parts from the loose parts bags in a small container to keep them from being lost IMPORTANT IMPORTANT PROTECTIVE PLASTIC BAG...

Page 5: ...turned off at the main fuse or circuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign obje...

Page 6: ...the switch cover assembly onto the fan motor switch cover adapter plate Align the switch cover assembly switches with the clearance notches in the motor assembly switch cover adapter plate Secure the cover using three 8 32 x 1 4 flat head screws supplied NOTE Do not pinch wires between the fan motor assembly and switch cover assembly NOTE Take care not to scratch fan housing when installing blades...

Page 7: ...LY SWITCH COVER CONNECTOR MOTOR ASSEMBLY CONNECTOR SWITCH CHAIN BUSHING Figure 5 HAIRPIN CLIP CLEVIS PIN MOTOR COUPLING 5 16 18 x 1 4 SETSCREW Figure 7 properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 13 Install the 5 16 18 x 1 4 setscrew into the threaded hole on the motor coupling 14 While pulling up on the down...

Page 8: ...white leads that are 80 long Before installing fan measure up approx imately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads CEILING COVER PIN DOWNROD HANGER BALL SETSCREW Figure 10 FAN MOTOR ASSEMBLY DOWNROD MOTOR COVER 8 32 x 1 4 PAN HEAD SCREW 4 Figure 8 MOTOR COVER COUPLING COVER DOWNROD GROMMET CEILING COVER Fig...

Page 9: ...9 Model No CF3600 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 12 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 13 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box...

Page 10: ...ely connect wires with wire connectors supplied Figure 14 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 14 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 14 After connections have been made turn leads upward and carefully push leads into the outlet box with...

Page 11: ...uld damage the motor or the blades and create the possibility of an electrical shock WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution...

Page 12: ...tain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER Model No CF3600 BP7384 Camden CF3600 3 12 09 12 37 PM Page 12 ...

Page 13: ...9 12 Coupling Chain 1 13 Pendant 1 14 Screw Flat Head Switch Cover 4 15 Setscrew 1 16 Screw Pan Head 4 17 Hex Wrench 1 18 Cover Ceiling 1 761795 9 761795 8 19 Cover Coupling 1 763631 763631 1 20 Cover Fan Motor 1 763633 763633 1 21 Motor Assembly 1 762508 762508 22 Medallion set of four 763896 763896 1 23 Flange set of four 763636 763636 1 24 Cover Assembly Switch 1 763866 763866 1 25 Harness Elec...

Page 14: ...crews in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in the hanger ball 1 Tighten the setscrew in the excessively downrod assembly is loose hanger ball downrod assembly 2 Screws securing fan blades 2 Check to be sure screws which to motor are loose attach the fan blade to the motor are tight 3 Fan blades are not seated 3 Check to be sure that the properly screws securing the fan...

Page 15: ...nsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defe...

Page 16: ... No F40BP73840000 Printed in China 03 09 Form No BP7384 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Model No CF3600 BP7384 Camden CF3600 3 12 09 12 37 PM Page 16 ...

Reviews: