background image

Product Data Document

420ds9b

July 10, 2007 - Page 3

ControlWave Upgrade Kits

www.EmersonProcess.com/Remote

Remote Automation Solutions

2 port comm card supports existing comm 

options (MIB, TIB, RDI, 1200/9600B Modems) 

on port B  

Configurable RS232/RS485 – 115.2 K baud

Serial ports are 9 pin ‘D’ connectors with 

standard 33XX pin out 
ESD protection on RS 485 ports - IEC 801 

Keypad/Display Support

The CW_10, CW_30, and CW_35 CPUs support 

the local 33XX local and remote Keypad/Display 

units via existing display interface connections. The 

CW_30 and CW_35 also support the ControlWave 

2-button and 25 button Display/Keypad units via 

standard Cat-5 cable with RJ-45 connectors. 

Environmental Specifications

Operating Temperature range: -40 to 70oC (-40 

to 158oF), storage up to 85oC 
Relative Humidity: 15-95% non-condensing 
Vibration: 1.0g for 10-150 Hz - 0.5g for 150Hz to 

2000Hz 
RFI Susceptibility: 3V/m – 80 MHz to 1000Mhz 

(EN50082-2) 

Power Consumption

CPU without Ethernet: 2 watt 
CPU with 1 Ethernet: 3 watt 
CPU with 2 Ethernet: 4 watt 
MFIB (Watchdog off): 1 watt 
MFIB (Watchdog on): 1.9 watt 
CW_XX 2 port comm.: 0.5 watt 
CW_XX 4 port comm.: 1 watt 

Hazardous Area Approvals 

FM approved as non-incendive for operation in 

Class I, Division 2 hazardous areas









Ordering Information

3310 Upgrade Kits

CW_10 Kit - 12 Vdc

includes CPU & MFIB: 396807-01-1-EXCH

CW_10 Kit - 24 Vdc 

 includes CPU & MFIB: 396807-02-0-EXCH 

3330 Upgrade Kits 

CW_30 CPU, 2 serial, without Ethernet: 

396807-03-8-EXCH

CW_30 CPU, 2 serial, with one Ethernet: 

396807-04-6-EXCH

CW_30 CPU, 2 serial, with two Ethernet: 

396807-05-4-EXCH

CW_30 - 2 Port Enhanced Comm Board: 

396807-06-2-EXCH

CW_30 - 4 Port Enhanced Comm Board:

396807-07-0-EXCH

3335 Upgrade Kits

CW_35 CPU, 2 serial, with two Ethernet

 

396807-09-7-EXCH

CW_35 - 2 Port Enhanced Comm Board

 

396807-12-7-EXCH

CW_35 - 4 Port Enhanced Comm Board

 

396807-11-9-EXCH

3331 Upgrade Kit

CW_31 CPU, 2 serial, one Ethernet

 

396807-10-0-EXCH

Summary of Contents for Bristol ControlWave CW_10

Page 1: ...monly used analog discrete and counter I O cards as well as modems and radios currently installed in the RTUs Communication compatibility is maintained through the same use of BSAP and Modbus proto cols as were used in the 33XX Benefits The ControlWave architecture offers several ad vantages over existing 3310 3330 3335s including increased compatibility with industry standards such as IEC 61131 3...

Page 2: ...with training to do the translation or you can rely on our Application Support Group to do the translation for you Specifications CW_10 CW_30 and CW_35 CPU 32 bit 150 MHz ARM processor Memory battery backup 7000 hours Optional one or two independent 10 100 Base T ports with RJ 45 connectors CW_30 and CW_35 only Ethernet port isolation 500 Vdc One 3 pin Utility Port for Flash downloading system fla...

Page 3: ...50Hz to 2000Hz RFI Susceptibility 3V m 80 MHz to 1000Mhz EN50082 2 Power Consumption CPU without Ethernet 2 watt CPU with 1 Ethernet 3 watt CPU with 2 Ethernet 4 watt MFIB Watchdog off 1 watt MFIB Watchdog on 1 9 watt CW_XX 2 port comm 0 5 watt CW_XX 4 port comm 1 watt Hazardous Area Approvals FM approved as non incendive for operation in Class I Division 2 hazardous areas Ordering Information 331...

Page 4: ...lity RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchas...