Emerson Bettis RP3E Installation, Operation And Maintenance Manual Download Page 14

World Area Configuration Centers (WACC) offer sales support, service, 

 

inventory and commissioning to our global customers.  

Choose the WACC or sales office nearest you:

www.emerson.com/bettis

VCIOM-15746-EN ©2021 Emerson. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson Electric Co.
Bettis

TM

 is a mark of one of the Emerson family of companies.

All other marks are property of their respective owners.

The contents of this publication are presented for information purposes 
only, and while effort has been made to ensure their accuracy, they are not 
to be construed as warranties or guarantees, express or implied, regarding 
the products or services described herein or their use or applicability. 
All sales are governed by our terms and conditions, which are available 
on request. We reserve the right to modify or improve the designs or 
specifications of our products at any time without notice.

For complete list of sales and manufacturing sites, please visit 

www.emerson.com/actuationtechnologieslocations

 or contact us at 

info.actuationtechnologies@emerson.com

NORTH & SOUTH AMERICA

19200 Northwest Freeway
Houston TX 77065
USA
T +1 281 477 4100

Av. Hollingsworth
325 Iporanga Sorocaba
SP 18087-105
Brazil
T +55 15 3413 8888

ASIA PACIFIC

No. 9 Gul Road
#01-02 Singapore 629361
T +65 6777 8211

No. 1 Lai Yuan Road
Wuqing Development Area
Tianjin 301700
P. R. China
T +86 22 8212 3300

MIDDLE EAST & AFRICA

P. O. Box 17033
Jebel Ali Free Zone
Dubai
T +971 4 811 8100

P. O. Box 10305
Jubail 31961
Saudi Arabia
T +966 3 340 8650

24 Angus Crescent
Longmeadow Business Estate East
P.O. Box 6908 Greenstone
1616 Modderfontein Extension 5
South Africa
T +27 11 451 3700

EUROPE

Holland Fasor 6
Székesfehérvár 8000
Hungary
T +36 22 53 09 50

Strada Biffi 165
29017 Fiorenzuola d’Arda (PC)
Italy
T +39 0523 944 411

Summary of Contents for Bettis RP3E

Page 1: ...Bettis RTS Relay Board RP3E Electric Actuator Installation Operation and Maintenance Manual VCIOM 15746 EN Rev 0 June 2021 ...

Page 2: ...on Details June 2021 Installation Operation and Maintenance Manual VCIOM 15746 EN Rev 0 Revision Details Revision Details No Date Version Type of Change 1 June 2021 0 General update Migration to new template ...

Page 3: ...Maintenance Manual VCIOM 15746 EN Rev 0 Table of Contents June 2021 Table of Contents Table of Contents Section 1 Tools Tools 1 Section 2 Material Material 2 Section 3 Installation Installation 3 Section 4 Programming Programming 8 ...

Page 4: ...Notes June 2021 Installation Operation and Maintenance Manual VCIOM 15746 EN Rev 0 This page is intentionally left blank ...

Page 5: ... EN Rev 0 June 2021 Tools 1 Section 1 Tools Section 1 Tools WARNING Remove all power supplies before doing the exchange Act always with caution during the exchange Needle nose pliers Screw driver phillips Screw driver flat Allen key 5 Socket wrench 5 Figure 1 ...

Page 6: ... 0 Material 2 Section 2 Material Section 2 Material 1x relay board RP3E6A ID 13009 1x adapter cable ID 16504 2x steel screw M3x16 ID 952 3x plastic distance 8 mm ID 9896 1x plastic screw M3x15 ID 9895 1x plastic nut M3 ID 7084 2x lock plates M3 red ID 13674 Figure 2 Figure 3 ...

Page 7: ...ion 3 Installation Section 3 Installation Unscrew the 4 hexagon socket screws from the cover and remove it carefully Mind the connection cable between display and logic board Figure 4 Unscrew the 4 cross recessed screws from the existing logic board and afterwards tilt it carefully to you Figure 5 ...

Page 8: ...ection 3 Installation Remove carefully the connected cables ribbon cable 6 8 10 poles plugs Afterwards you can remove the logic board from the control unit and disconnect the 2nd ribbon cable on the back Figure 6 Remove the two marked with the red arrows steel distances in the housing Figure 7 ...

Page 9: ...stimated holes next to multi pin connector in logic board plastic distances and relay board and secure the screws with the red lock plates For the 3rd hole use the plastic screw M3x15 and secure it with plastic nut Figure 8 Connect the relay board with the multi pin connector from the logic board NOTE 4 pins must stay free see FIgure 9 Orientation brings the mounting holes of both boards they must...

Page 10: ...peration and Maintenance Manual VCIOM 15746 EN Rev 0 Installation 6 Section 3 Installation Connect the adapter cable with the 10 and 6 pole connector after connect blue connectors with related one on the relay board Figure 10 ...

Page 11: ...of cables or other parts Figure 11 Connect cable between display cover and logic board Perform a Firmware update before installing display cover on the unit This update is important for the following programming steps use FW version display 1507 logic 219 or higher For a detailed description on how to preform a firmware update please refer to separate manual During display cover installation pay a...

Page 12: ...ramming request download of SMARTTOOL2 through your Sales Representative After the successful installation and registration connect with the actuator Use the Wizard and choose function Install Extension Kit and press Apply Figure 13 At the line RP3E6A 6x Relay Outputs 3x Inputs press Apply and confirm the installation by pressing Ja Figure 14 ...

Page 13: ...nance Manual VCIOM 15746 EN Rev 0 June 2021 Programming 9 Section 4 Programming After installation press the Refresh Button In parameter group 9 Bin Input and 10 Relay you can define the functionality of the different relays Figure 15 ...

Page 14: ...We reserve the right to modify or improve the designs or specifications of our products at any time without notice For complete list of sales and manufacturing sites please visit www emerson com actuationtechnologieslocations or contact us at info actuationtechnologies emerson com NORTH SOUTH AMERICA 19200 Northwest Freeway Houston TX 77065 USA T 1 281 477 4100 Av Hollingsworth 325 Iporanga Soroca...

Reviews: