Installation
Table 2�
BETTIS™ PressureGuard™ Components and Descriptions
Item
Component
Description
1
Operator
Rotary or linear (shown) hydraulic operator.
2
Line Valve
Ball, plug, and others, quarter turn or non-6A linear valve
(shown).
3
Handpump
Used to manually pressurize BETTIS™ PressureGuard™
and open a valve.
4
Filter
Filters hydraulic fluid before entering Handpump (3) and controls.
5
Check Valve
Holds high pressure when Handpump (3) is stroked.
6
Gauge, LP
Stainless steel liquid-filled gauge shows the control pressure
(low-range).
8
Breather
Ventilates Reservoir (24) as volume changes.
9
Gauge, HP
Stainless steel liquid-filled gauge shows the operator pressure
(high-range).
10
High-Pressure Relief Valve
A high-pressure relief valve protects the operator and control
system from overpressurization caused by thermal expansion.
12
Pressure Regulator
Regulates the hydraulic fluid pressure in the control circuit.
13
Low-Pressure Relief Valve
A low-pressure relief valve protects control circuit from
overpressurization caused by thermal expansion.
14*
Pressure Pilot
Directly monitors pipeline pressure and can trip ESD.
ns*
Selector Valve
Allows selection of automatic command (via Pressure Pilot (14)
and/or Solenoid Valve (20)) or manual command (by technician
at BETTIS™ PressureGuard™ using Reset Valve (23) and/or
Handpump (3)).
20*
Solenoid Valve, N.C.
Allows remote command of ESD.
23
Reset Valve
A latching trip relay reset valve provides quick closing speeds.
A manual reset function for local reopening of the valve and
manual closing function.
24
Fluid Reservoir
Contains the hydraulic fluid for the operator Cylinder and controls.
26
Fluid Level Gauge
For visual indication of the hydraulic fluid level and condition.
27
Accumulator
Prevents cyclic transfer due to temperature change of fluid from
high pressure operator supply circuit to the low pressure control
circuit, and thereby prevents temperature induced creep of
the operator.
-*
Isolation Test Valve
Typically used to isolate the pressure from the pipeline to the
sensing device (Pressurematic™).
* = Optional component, per customer specification.
ns = Not shown.
Summary of Contents for Bettis PressureGuard
Page 2: ......
Page 23: ...March 2014 Installation and Maintenance Manual E 90090005 Rev A 20 Appendix Appendix 2 ...