background image

Instruction Manual

D103374X012

89000 Valve

September 2015

12

Emerson Process Management 

Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore

www.Fisher.com

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.

E

 

2009, 2015 Fisher Controls International LLC. All rights reserved.

Baumann, Fisher, and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co.
Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property
of their respective owners.

Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.

Summary of Contents for Baumann 89000

Page 1: ...aseptic process systems These valves meet FDA and USP CLVI standards They are designed to drain freely from inlet to outlet In sanitary and aseptic valve applications the surface finish of all wetted parts is of the utmost importance and needs to be free of pits and cracks The Baumann 89000 series valves meet all of these requirements The 89000 control valve covers a wide range of applications in ...

Page 2: ...and accessory installation operation and maintenance To avoid personal injury or property damage it is important to carefully read understand and follow all the contents of this manual including all safety cautions and warnings If you have any questions about these instructions contact your Emerson Process Management sales office before proceeding Educational Services For information on available ...

Page 3: ...ssures and temperatures to the valve could result in parts damage malfunction of the control valve or loss of control of the process Do not expose this product to service conditions or variables other than those for which the product was intended If you are not sure what these conditions are you should contact your Emerson Process Management sales office for more complete specifications Provide th...

Page 4: ...valve packing box may contain process fluids that are pressurized even when the valve has been removed from the pipeline Process fluids may spray out under pressure when removing the packing hardware or packing rings or when loosening the packing box pipe plug D Check with your process or safety engineer for any additional measures that must be taken to protect against process media Note Whenever ...

Page 5: ...llow you to turn the stem Do not place valve in a vise This can distort the shape of the valve CAUTION Prior to performing maintenance on the valve isolate the valve vent the process pressure and shut off supply and signal air lines to the actuator Disassembly Actuator Removal Access to the internal components of the valve body can be accomplished with the actuator removed Air to Close Actuators 1...

Page 6: ...upper valve body key 1b and off of the plug and stem key 12 2 Remove the plug and stem key 12 from the upper valve body key 1b 3 Unthread the middle valve body clamp bolts and remove the bolts from the middle body clamp key 6 Take the middle body clamp key 6 off and slide the lower body key 1c away from the upper body key 1b Be sure not to tear the O ring seal 4 Once the lower body key 1c has been...

Page 7: ...use they may void your warranty might adversely affect the performance of the valve and could cause personal injury and property damage Figure 3 Baumann 89000A Angle Valve Assembly E1337 Figure 4 Baumann 89000I Inline Valve Assembly E1338 4 11 10 14 2 3 8 9 12 Table 1 Baumann 89000 Common Parts Key Number Description Key Number Description 1a Upper Angle Valve Body 8 Stem Locknut 1b Upper Inline V...

Page 8: ... 4 7 GE56517X012 25 1 Angle 10 GE56144X012 89T001 89T001 X022 Inline 10 GE56518X012 89T007 89T007 X022 40 1 1 2 Angle 21 GE53538X012 89T002 89T002 X022 Inline 21 GE56519X012 89T008 89T008 X022 50 2 Angle 21 GE52287X022 89T003 89T003 X022 33 GE52287X012 Inline 33 GE56520X012 89T009 89T009 X022 3 Angle 79 GE52860X012 89T005 89T005 01 Inline 79 GE56521X012 89T011 89T011 X022 80 Angle 99 GE56522X012 8...

Page 9: ...01 20 3 4 1 9 62 7 2 5 50 1 97 344 13 5 331 13 165 6 5 261 10 3 66 35 2 61 53 65 2 11 20 3 4 4 7 62 7 2 5 50 1 97 344 13 5 331 13 165 6 5 261 10 3 62 70 2 47 50 00 1 97 25 1 10 62 7 2 5 50 1 97 344 13 5 331 13 270 10 6 261 10 3 61 75 2 43 49 05 1 93 40 1 1 2 21 102 7 4 90 3 54 445 17 5 432 17 270 10 6 261 10 3 104 10 4 1 91 40 3 60 50 2 33 112 7 4 4 100 3 94 459 18 1 446 17 6 270 10 6 261 10 3 112...

Page 10: ...m Inch 15 1 2 62 7 2 5 50 1 97 34 5 1 36 50 1 97 165 6 5 366 14 4 127 5 20 3 4 62 7 2 5 50 1 97 34 5 1 36 50 1 97 165 6 5 366 14 4 127 5 25 1 102 7 4 90 3 54 48 1 89 74 2 91 165 6 5 464 18 3 153 6 40 1 1 2 102 7 4 90 3 54 48 1 89 74 2 91 270 10 6 464 18 3 153 6 50 2 112 7 4 4 100 3 94 56 2 20 85 3 35 270 10 6 488 19 2 153 6 80 3 147 7 5 6 130 5 12 78 3 07 116 4 57 270 10 6 581 22 9 153 6 100 4 155...

Page 11: ...Instruction Manual D103374X012 89000 Valve September 2015 11 ...

Page 12: ...e available upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice E 2009 2015 Fisher Controls International LLC All rights reserved Baumann Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co Emerson Process Management Emerson and the Emerson log...

Reviews: