background image

AVENTICS™

2

Visit our website at Emerson.com/AVENTICS

CAUTION! Dangerous operating conditions may occur when using the programming interface on the valve as the valve may possibly not 
react to the analog setpoint any more.
Provide for protection against uncontrolled movement of equipment when putting the valve into operation and before making any 
modifications to the valve settings.

NOTICE

The information in this manual is subject to change without notice.

In no event shall Emerson be liable for technical or editorial errors or omissions. Neither is any liability assumed for accidental or consequential damages 

arising out of or in connection with the supply or use of the information contained herein.

THIS MANUAL CONTAINS INFORMATION PROTECTED BY COPYRIGHT. NO PART OF THIS DOCUMENT MAY BE PHOTOCOPIED OR REPRODUCED IN ANY FORM 

OR MANNER WHATSOEVER WITHOUT PRIOR WRITTEN PERMISSION FROM EMERSON.

E S D

This product complies with the essential requirements of the EMC Directive 89/336/EEC and its amendments. It is CE-approved. A separate Declaration of 
Conformity is available on request.
A separate Declaration of Incorporation relating to the EU Directive 89/392/EEC Annex II B is available on request. Please provide ordering code and serial 
numbers of products concerned.

DECLARATION OF INCORPORATION

according to Machinery Directive 89/392/EEC, Annex II B

We herewith declare that the version of the product described in this installation manual is intended to be incorporated into or assembled with other machinery and that 
it must not be put into service until the machinery into which it is to be incorporated has been declared in conformity with the provisions of Council Directive 89/392/EEC, 
Annex IIB.
Handling, assembly and putting into service and all settings and adjustments must be done by qualified, authorised personnel only.

This product contains electronic components sensitive to electrostatic discharge. 
An electrostatic discharge generated by a person or object coming in contact with 
the electrical components can damage or destroy the product.
To avoid the risk of electrostatic discharge, please observe the handling precautions 
and recommendations contained in standard EN 100015-1. Do not connect or 
disconnect the device while it is energised.

C AU T I O N

OBSERVE PRECAUTIONS

FOR HANDLING

ELECTROSTATIC SENSITIVE DEVICES

!

1

1.1

1.2

1.3

1.4

2

3

4

5

6

7

7.1

7.2

8

9

10

Table of Contents

Sentronic

D

 Description 

3

 

How To Order 

3

 

Operating Elements 

4

 

Manual Pressure Regulation 

4

 

Operating Modes 

4

 

Electrical Connection 

5

 

Analog Setpoint - Outlet Pressure 

6

 

Pneumatic Connection 

7

 

Factory Settings for a Standard Valve 

7

 

Field-programmable settings 

8

 

Technical characteristics 

8

 

Fluid characteristics 

8

 Specifications 

8

 Accessories 

9

 

Maintenance and care 

9

 

Dimensions and weights 

10

Summary of Contents for AVENTICS Sentronic D

Page 1: ...Installation Manual SentronicD Digital Electronic Pressure Regulator ...

Page 2: ...ORPORATION according to Machinery Directive 89 392 EEC Annex II B We herewith declare that the version of the product described in this installation manual is intended to be incorporated into or assembled with other machinery and that it must not be put into service until the machinery into which it is to be incorporated has been declared in conformity with the provisions of Council Directive 89 3...

Page 3: ...ters can be changed with the additional software called DaS The DaS program Data Acquisition Software ensures that all parameters used by the valve can be changed This flexibility allows the valve to be adapted to the application and enables the optimization of its response time overshoot and preci sion After having set the optimum parameters you can save them in a project file for your personal u...

Page 4: ...ow buttons are released Press the left arrow button or DOWN arrow to reduce the outlet pressure press the right arrow button or UP arrow to increase the outlet pressure The yellow LED is on permanently during manual mode Exit this operating mode by pressing both arrow buttons simultaneously or by turning off the power supply for a short time 1 4 Operating Modes Shut off If the command signal falls...

Page 5: ...or 0 20 4 20mA Control Analog output Black Only at current output max 500 ohm Digital output Gray PNP when setpoint is reached setpoint feedback Inductive load M4 connection on valve body Connector housing Shield 200mA max 4 8W AVENTICS 6 Wire Cable Color Code Brown Blue White Yellow 1 The valve must only be supplied with 24V DC at a tolerance of 15 10 and a max ripple of 10 no supply via diode br...

Page 6: ...e DaS program Switch to Custom in the Setpoint setting section The zero range is max 50 Setpoint span The span of the output pressure can be changed via the DaS program Switch to Custom in the Setpoint setting section The span is between 10 and 100 Offset adjustment F a c t o r y s e t t i n g SHUT OFF Max outlet pressure PMR 50 PMR 20mA 4 12 mA 0 50 mV 0 1 mA 4 08 mA 0 50 PMR 10 V 20 mA 0 Span ad...

Page 7: ...mA 6 bar device 6 bar at 10 V 20 mA 10 bar device 10 bar at 10 V 20 mA The air flow is from port 1 to port 2 Inch screw connections pipe threads must be used Each screw connections must be lined with a fitting synthetic sealing disc Do not use Teflon sealing tape or hemp as they may get inside the valve and damage it Use an appropriate silencer at port 3 The exhaust time may vary depending on the ...

Page 8: ...n that will give a voltage drop of less than 2 volts at 2A 7 1 Fluid Characteristics Fluids Air or neutral gas filtered at 50 µm free of condensate lubricated or not Ports 1 8 1 4 3 8 NPT or GTap see section 3 Max Inlet Pressure see section 3 Temperature Fluid 32 F 140 F 0ºC 60ºC Temperature Ambient 32ºF 122ºF 0 C 50 C Hystersis 1 of span Linearity 0 5 of span Repeatability 0 5 of span Minimum Set...

Page 9: ...2m cable with 9 pin Sub D plug connector 88100732 RS 232 cable converter 2m cable with 9 pin Sub D screw connector 833 993708 5 Pin 12mm FEMALE 90 DEGREE Field Attachable Connectors PG 9 Cable Gland TD05F20000000000 5 Pin 12mm FEMALE Straight Field Attachable Connectors Model Number PG 9 Cable Gland TC05F20000000000 Micro Female 5 Pole Straight 6 Wire 22 AWG Shielded 3 Meter TC0503MMS000671Y 5 Met...

Page 10: ... lbs kg Dimensions Inches mm Weight in lbs kg Connector Fixing holes M4 thread G1 8 G1 4 Programming Interface Hole for M4 screw M4 hole for earth screw G1 8 G1 4 Hole for M4 screw M12x1 Inline version DN 4 Weight 1 23 0 56 Inline version DN 8 Weight 2 49 1 13 SentronicD INSTALLATION MANUAL ...

Page 11: ... Inches mm Weight in lbs kg Manifold DN 4 Hole for M4 screw Hole for M4 screw 3 8 GTap 1 8 GTap 1 4 G T a p 3 8 GTap 3 8 GTap 3 8 GTap 0 31 8 1 93 49 0 55 14 1 69 43 1 38 35 1 61 41 0 79 20 0 83 21 2 17 55 1 26 32 2 24 57 0 24 6 1 28 32 5 0 45 11 5 3 74 95 3 94 100 2 12 54 SentronicD INSTALLATION MANUAL ...

Page 12: ...DN 8 Dimensions Inches mm Weight in lbs kg Hole for M4 screw Hole for M4 screw 0 83 21 0 20 5 0 45 11 5 1 54 39 4 53 115 4 72 120 0 31 8 1 02 26 2 40 61 0 71 18 2 68 68 2 01 51 1 81 46 2 01 51 2 17 55 1 38 35 2 68 68 1 2 GTap 1 8 G T a p 1 2 GTap 1 2 GTap 3 8 GTap 1 2 GTap SentronicD INSTALLATION MANUAL ...

Reviews: