3

THIS FAN IS SUITABLE FOR DAMP LOCATIONS

SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED

DECKS...ANYWHERE THERE IS A ROOF OVERHEAD.

This Manual is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Do not install or use fan if any part is
damaged or missing. Call Toll-Free:

1-800-654-3545

!

WARNING

This product is designed to use only
those parts supplied with this product
and/or any accessories designated
specifically for use with this product by
Emerson Electric Co. Substitution of
parts or accessories not designated for
use with this product by Emerson Electric
Co. could result in personal injury or
property damage.

!

WARNING

Tools Needed for Assembly

One Phillips head screwdriver
One wire stripper
One stepladder

Materials

Wiring, outlet box and box connectors
must be of type required by the local code.
The minimum wire would be a 3-conductor
(2-wire with ground) of the following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Before assembling your ceiling fan, refer
to section on proper method of wiring
your fan (Page 9). If you feel you do not
have enough wiring knowledge or
experience, have your fan installed by a
licensed electrician.

!

WARNING

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each
step is completed, place a check mark in the box. This will insure that all steps
have been completed and will be helpful in finding your place should you be
interrupted.

NOTE: If you are uncertain of part
description, refer to exploded view
illustration.

a. Fan motor assembly
b. One coupling cover
c. One ceiling cover
d. Five fan blades
e. One lower housing
f. One light kit assembly
g. One hanger bracket
h. One hanger ball/4.5” downrod assembly
i. One lower glass
j. One fan/light remote control

(transmitter and receiver)

k. Two 60-watt (maximum) candelabra

base bulbs

l. One loose parts bag containing:

1. One clevis pin
2. One hairpin clip
3. Three 12 ga. wire connectors
4. Six 18 ga. wire connectors
5. Two #8-32 x 1-1/4” threaded studs
6. Two #8 external tooth lockwashers
7. Two #8-32 knurled knobs
8. Sixteen M5 x 12mm washer head

screws

9. Seven M4 x 10mm serrated head

screws

10. One balancing kit

1.

Open carton containing fan. Remove
top half of styrofoam unit. Remove
parts and check to see that you have
received the following parts:

UL Model No.: CF930

BP7332-2 CF930 Atomical  9/23/10  3:29 PM  Page 3

Summary of Contents for ATOMICAL CF930BS02

Page 1: ...rm No BP7332 2 UL Model No CF930 READ AND SAVE THESE INSTRUCTIONS Net Weight 18 0 Lbs ATOMICAL 52 Damp Location Ceiling Fan Owner s Manual CF930BS02 CF930ORB02 CF930WW02 Model No BP7332 2 CF930 Atomical 9 23 10 3 29 PM Page 1 ...

Page 2: ...only used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Fol...

Page 3: ...age 9 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOT...

Page 4: ...OUPLING COVER C CEILING COVER D FAN BLADES E LOWER HOUSING F LIGHT KIT ASSEMBLY J FAN LIGHT REMOTE CONTROL G HANGER BRACKET H HANGER BALL 4 5 DOWNROD ASSEMBLY L LOOSE PARTS BAG I LOWER GLASS K 60 WATT CANDELABRA BULBS NOTE Place the parts from the loose parts bags in a small container to keep them from being lost IMPORTANT IMPORTANT CARDBOARD SHIPPING RETAINER 2 PROTECTIVE PLASTIC BAG UL Model No ...

Page 5: ...function properly and may be damaged if used with any wall dimmer switch or control other than the Emerson Electric Fan Light Wall Control supplied with the fan or an optional Emerson Electric SR100 Remote Control Electrical Requirements Ceiling Fan Procedures How to Assemble Your Ceiling Fan Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned...

Page 6: ...ING DOWNROD HAIRPIN CLIP DOWNROD HAIRPIN CLIP MOTOR COUPLING SETSCREW 2 CLEVIS PIN Figure 2 HAIRPIN CLIP CLEVIS PIN MOTOR COUPLING COUPLER COVER CEILING CANOPY SETSCREW 2 Figure 3 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 2 could result in t...

Page 7: ...g fan measure up approx imately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Turn fan motor assembly upside down in preparation for mounting fan blades Position the top and bottom halves of the styrofoam packaging on end with solid styrofoam facing outward Set side by side on the floor with a six to eight inch g...

Page 8: ...ly and lower housing 10 Connect the black wire of the light kit assembly to the blue wire of the fan motor assembly using one wire connector supplied Connect the white wire of the light kit assembly to the white wire of the fan motor assembly using a supplied wire connector Figure 8 WIRE CONNECTOR WHITE WIRE FROM THE LIGHT KIT ASSEMBLY WHITE WIRE FROM FAN MOTOR ASSEMBLY BLUE WIRE FROM FAN MOTOR AS...

Page 9: ...sing wire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 2 Refer to Figures 13 and 14 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding c...

Page 10: ...ECEIVER WHITE WIRE FAN WHITE WIRE FAN BLACK WIRE ANTENNA AC IN N AC IN L FO R LI G H T TO M O TO R N RECEIVER BLUE WIRE RECEIVER BLACK WIRE RECEIVER WHITE WIRE SUPPLY WHITE WIRE NEUTRAL SUPPLY BLACK WIRE HOT GROUND WIRE GREEN GROUND WIRE FROM HANGER BALL FAN BLUE WIRE 1 1 4 THREADED STUD 2 T O M O T O R L Figure 13 Figure 14 UL Model No CF930 STANDARD ON OFF WALL SWITCH OR OPTIONAL SW406 WALL CONT...

Page 11: ... and installing the two knurled knobs supplied Figure 15 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling 8 EXTERNAL TOOTH LOCKWASHER 2 CEILING COVER 1 1 4 THREADED STUD 2 8 32 KNURLED KNOB 2 Figure 15 LIGHT KIT ASSEMBLY SOCKET 2 60 WATT MAX CANDELABRA BASE BULB 2 Figure 16 FLAT AREA 3 RAISED DIMPLE 3 GLASS BOWL LOWER HOUSING ASSEMBLY Figure 17 7 Place the...

Page 12: ...mote Control Procedures General Your Emerson Ceiling Fan Light Remote Control consists of hand held transmitter and a receiver which is mounted under the fan ceiling cover The remote control is designed to separately control your ceiling fan speed and light intensity There are four push buttons to set the fan speed and turn the fan off The light push button turns the light on and off and controls ...

Page 13: ... STORAGE BRACKET TO INSTALL BRACKET TO WALL SLIDE THE COVER UP TO EXPOSE THE SCREW HOLES FOR INSTALLATION COVER SCREW HOLES 2 WALL BRACKET IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control AIRFLOW REVERSING SWITCH FAN MOTOR ASSEMBLY Figure 20 3 If airflow is desired in the opposite direction turn the fan off and wait for ...

Page 14: ...jury or property damage WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories UL Model No CF930 Fan Light Fails to...

Page 15: ...n motor housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling are 1 Raise coupling cover and tighten excessively not tightened securely setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blades 3 Check to be sure screws which to motor are loose attach the fan blade to the ...

Page 16: ...en removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER UL Model No CF930 BP7332 2 CF930 Atomical 9 23 10 3 29 PM Page 16 ...

Page 17: ...ead M5 x 12mm 16 12 Screw Serrated Head M4 x 10mm 7 13 Kit Balancing 1 14 Cover Ceiling 1 763534 BS 763534 ORB 763534 WW 15 Cover Coupling 1 763267 BS 763267 ORB 763267 WW 16 Housing Lower 1 763270 BS 763270 ORB 763270 WW 17 Harness Wiring 1 763274 763274 763274 1 18 Light Kit Assembly 1 763271 763271 763271 19 Glass Lower 1 763273 763273 1 763273 20 Blade Set full set for one fan 763275 763275 1 ...

Page 18: ... the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a Cl...

Page 19: ...ponsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any de...

Page 20: ... F40BP73320002 Printed in China 09 10 Form No BP7332 2 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 UL Model No CF930 BP7332 2 CF930 Atomical 9 23 10 3 29 PM Page 20 ...