Section 7: Disassembly and Reassembly
Disassembly and Reassembly
7.2
Disassembly of Spur Gear Reduction Unit
•
Remove the cover by loosening the cover bolts with a spanner.
•
Each time the cover is removed, the gasket sealing is lost as it is a liquid sealant.
Re-apply gasket sealant (Loctite no. 596 or equivalent).
Figure 8
Spur Gear Bolts
•
Both spur pinions and spur gears can be removed with a circlip plier once the cover
is removed.
•
Remove the spur gear unit casing by loosening the allen cap screws with which it is
mounted on the main AT Series GB casing.
Figure 9
Spur Housing Disassembled