Menu 4
Commander SK Advanced User Guide
71
Issue Number: 9 www.controltechniques.com
The maximum for Pr
4.08
and Pr
4.20
is defined by this parameter.
0
: OFF Low speed thermal protection mode disabled
1
: On Low speed thermal protection mode enabled
See Pr
on page 68 for details.
Pr
4.26
shows the torque producing current (Pr
4.02
) as a percentage of the active torque producing current, but with an additional adjustment above
base speed so that this parameter shows percentage torque. Below base speed, Pr
4.26
is equal to Pr
4.20
. Above base speed the percentage
torque producing current (Pr
4.20
) is adjusted as follows:
Pr
4.26
= Pr
4.20
x motor rated frequency (Pr
5.06
) /post ramp reference (Pr
2.01
)
Modification of this parameter may be required when using the drive with a high- speed motor, which inherently has low inductance.
This parameter should only be set to On if OI.AC trips are occurring when the drive is carrying out a mains loss stop or DC injection brake with a high
speed motor.
Only available with drive firmware V01.08.04 onwards (size 2 to 6).
4.24
User current maximum scaling
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
1
1
Range
0.0 to TORQUE_PROD_CURRENT_MAX%
Default
165.0
Update rate
Background
4.25
Low speed thermal protection mode
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Range
OFF(0) or On(1)
Default
OFF(0)
Update rate
Background
4.26
Percentage torque
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
1
1
Range
±USER_CURRENT_MAX %
Update rate
Background
4.27
Reduce internal current loop response
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Range
OFF (0) or On (1)
Default
OFF (0)
Update rate
Background
NOTE