Summary of Contents for 10C13T-41002

Page 1: ...I _MI _RSON THRU THE WALL ELECTRONIC AIR CLEANER INSTALLATION OPERATION SERVICE Model Nos 10C1 3T 41 002 14C1 3T 41 002 20C1 3T 41 002 MANUAL NO 846 0262 ...

Page 2: ...d using your air cleaner be sure to read these instructions carefully and observe _them in order to derive the maximum benefits from the superior performance built into the unit and help to avoid needless service costs that result from causes the manufacturer cannot control and cannot be covered in the warranty The units are available in three models Model TTW 10 designed for an air volume of up t...

Page 3: ...ht on floor 3 Release two knurled screws F G 2 at upper edge of grille open grille and slide it out of hinges at bottom by moving it to the left 4 Rotate two screen retainer latches either left or right to clear screen Lift screen out 5 Remove three screws one at each end and one at center of electrical enclosure cover and remove cover 6 Grasp the two spring clips at the points A FIG 3 and pull th...

Page 4: ...ll or ceiling extend a connecting duct to the rear of air cleaner frame with sheet metal screws NOTE Always tape all ductwork joints with duct tape to prevent dirt laden air from entering ducts After deciding upon the exact location make sure of the following before cutting out wall or ceiling area 1 Exact location of return air duct behind the wall or ceiling 2 Location is free of obstructions su...

Page 5: ...he air cleaner to insure maximum filtering efficiency The expansion or contraction rate of the transition should not exceed the ratio of 1 to 3 Seefigure 10 Once the duct connection to the framing is completed the air cleaner frame cabinet may be inserted into the framing cavity Before inserting the cabinet one of the three knockouts figure 15 should be removed for insertion of the 120 VAC input w...

Page 6: ...all strength Use basic concepts shown in figures 12 through 14 if your wall differs from the diagrams shown NOTE Thesame method for framing the air cleaner cutout _ be applied to ceiling joists when a ceiling installation is required 6 Cut out required opening in return air duct The duct cutout should fit air cleaner cabinet as closely as possible If duct is more than six inches from wall surfac e...

Page 7: ...e and black They should be matched to wires of the same color from electrical power source figure 18 Connect ground wire from power source directly to the green grounding wire provided in the junction box area This Thru the Wall electronic air cleaner is equipped with a solid state Air Flow monitor figure 16 that will automatically turn your air cleaner ON or OFF when ever the furnace fan is runni...

Page 8: ...ety spring clip at bottom center of cabinet d Continue to push cell inward at bottom until it latches into the spring clips one at each side of cabinet Make sure both clips are latched See FIG 19 13 Install screen and grille a Drop screen behind two screen clips at bottom of cabinet and fasten at upper edge with two spring retainer latches See FIG 2 b Engage pins at lower edge of grille into their...

Page 9: ...at the unit is defective SAFETY1NTERLOCK O N OFF SWITCH SWITCH J OPERATINGLIGHT I 0oi OF Ir i IIE I Figure 21 III I MAINTENANCE WASHING CELL AND SCREEN NOTE For top performance your electronic air cleaner should be cleaned at least every two months or more often in areasof extreme air borne dust 1 Remove two knurled screws and open the grille 2 Push ON OFF rocker switch at top to turn it off Figur...

Page 10: ...es of cell until water is clear d Flush cell frame along edges to dislodge any trapped dirt or lint e Flush and rinsescreenon both sides f Stand cell and screen up and allow them to drain for 2 hours 10 INSTALL CELL CAUTION When installing the cell in a ceiling installation make sure it is latched securely in place before releasing it Figure 20 a Grasp the cell firmly holding it a slight angle wit...

Page 11: ...ualified personnel WARNING The following procedures will expose hazardous live parts Disconnect electrical power to aircleaner before proceeding INDICATION ON OFF Switch Light on 1 Operating Light on ON OFF Switch Light off 1 Operating Light off 1 ON OFF Switch Light on Operating Light off 2 3 CORRECTIVE PROCEDURES Electric power is being supplied to the air cleaner and the unit is functioning Ele...

Page 12: ...REPAIR PARTS 11 14 15 12 ...

Page 13: ...inRelief Bushing Sensor Cover ElectricalEnclosurew label Screw Type B SMS No 8 x 1 2 Cell Assembly IonizingWire _ Pre filter Screw with Washer Grille Manual 10C13T F858 0707 F859 0292 F_ _0202 F876 0199 F844 0135 F808 0337 F888 0073 F888 0072 F857 0360 F811 0267 F843 0775 F825 0260 F870 0026 F831 0095 846 0262 PART NO 14C13T F858 0706 F859 0292 F876_ F876 0199 F844 0135 F808 0335 F888 0073 F888 00...

Page 14: ...WHITE RODGERS White Rodgers Division Emerson Electric Co Em 9797 Reavis Road St Louis MO 63123 I 314 577 1300 J ...