background image

4

Tools

 

and

 

Parts

Gather

 

the

 

required

 

tools

 

and

 

parts

 

before

 

starting

 

installation

Read

 

and

 

follow

 

the

 

instructions

 

provided

 

with

 

any

 

tools

 

listed

 

here

.

Tools

 

needed

Parts supplied

 

Check

 

that

 

all

 

parts

 

are

 

included

 

in

 

parts

 

package

.

Phillips

 

screwdriver

Scissors

Level

Tape

 

measure

Cordless

 

drill

 

and 

 

 

bit

Pencil

A Adhesive

 

seal 

 

.

(2)

B Foam

 

seal

.

C

.  

lock

 

frame

(

for

 

Wooden

 

windows

)(2) 

I

.  

sash lock

 

J

.  

Air conditioner

 

D

.  

lock

 

frame

(

for

 

Vinyl-Clad

 

windows

)(2) 

G Side

 

curtains

 (2)

.

A

B

C

I

D

J

H Top rail

.

H

E F

G

     1

 

/8"

     E. 3  screws(4)

 

/8"

     F. 3  screws(7)

 

/4"

Remove

 

packaging

 

materials

Remove

 

and

 

dispose

 

of

/

recycle

 

packaging

 

materials

Remove

 

tape and

 

glue residue

 

from

 

surfaces

 

before

 

turning

 

 

 

on

 

the

 

air

 

conditioner

Rub

 

a

 

small

 

amount

 

of

 

liquid

 

dish

 

soap

 

over

 

the

 

adhesive

 

with

 

your

 

fingers

Wipe

 

with

 

warm

 

water

 

and

 

dry

.

Unpack

 

the

 

Air

 

Conditioner

Do

 

not

 

use

 

sharp

 

instruments

rubbing

 

alcohol

flammable

 

fluids

or

 

abrasive

 

cleaners

 

to

 

remove

 

tape

 

or

 

glue

These

 

products

 

can

 

damage

 

the

 

surface

 

of

 

your

 

air

 

conditioner


Handle

 

the

 

air

 

conditioner

 

gently

.

WARNING

Excessive Weight Hazard

 

 

Use two or more people to move and install

 

   

 

   

 

 

 

air conditioner

 

.

Failure to do so can result in back or other injury

       

 

   

   

 

.

Remove top rail from the packaging material

.

Packaging

Top Rail

Summary of Contents for EARC5MD1H

Page 1: ...0 CVU PANTONE 653 CVU 10 BLACK 20 BLACK MODEL Mechanical Window Air Conditioner Thank you very much for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner 5 000 BTU ...

Page 2: ...ents INSTALLATION INSTRUCTIONS Unpack the Air Conditioner Prepare Air Conditioner for Installation Window Air Conditioner Installation Completer Installation Starting Your Air Conditioner AIR CONDITIONER USE Changing Air Direction Normal Sounds AIR CONDITIONER CARE 10 10 Cleaning the Front Panel 10 Repairing Paint Damage 10 TROUBLESHOOTING 11 9 Cleaning the Air Filter 10 ...

Page 3: ... or sideways to avoid damage to the compressor The wiring diagram is shown at nameplate on the air conditioner This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Chi...

Page 4: ...ce may differ from the one shown T o test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET on some devices a green light will turn on 3 Press TEST listen for click Reset button will trip and on some devices a green light will turn off 4 Press and release RESET listen for click Reset button will latch and on some devices a green light will turn on The pow...

Page 5: ... F 3 screws 7 4 Remove packaging materials Remove and dispose of recycle packaging materials Remove tape and glue residue from surfaces before turning on the air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Unpack the Air Conditioner Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove ta...

Page 6: ...ed without the side curtain panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model A With side curtain panels B Models A B 5K BTU 12 2 315mm min 5 22 37 4 5 559mm 960mm Read these ins...

Page 7: ...nditioner A B Attach Top Rail 1 Locate the bag of screws provided 2 Place the top rail on top of the air conditioner cabinet lining up the 4 holes in the top rail with the 4 holes on top of the air conditioner cabinet 3 Using four 10mm screws attach the top rail to the air conditioner cabinet A Curtain housing A Side curtain B Curtain top rail B Air conditioner cabinet B A 3 8 A B Top rail 3 screw...

Page 8: ...our model may differ from the one shown Window Air Conditioner Installation 2 Use a drill bit to drill a starter hole through the 3mm hole in the top rail 1 8 Attach Side Curtains to Window 1 Pull the left hand curtain out until it fits into the window channel 3 Insert one of the 3 4 9mm 1 screws through the left hand curtain and into the window sash A Window sash B Hole in side curtain C 3 4 scre...

Page 9: ...d prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING AIR CONDITIONER USE Operating your air conditioner properly helps you to obtain the best possible results This section explains proper air conditioner operation IMPORTANT If you turn off the air conditioner wait at least minutes 3 before turning it ba...

Page 10: ...ature Rotate the thermostat selector counter clockwise for lower cool settings Lower cool settings will provide higher room temperature To set the desired room temperature rotate the thermostat switch to the desired setting After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature Fan Speed Fan Only NOTE N...

Page 11: ...r in place 1 Turn off the air conditioner 3 Use a vacuum cleaner to clean the air filter If the air filter is very dirty wash it in warm water with a mild detergent Do not wash the air filter in the dishwasher or use any chemical cleaners Air dry the filter completely before replacing to ensure maximum efficiency 4 Replace the air filter back into the air conditioner and colse the front panel Clea...

Page 12: ... green light will turn on to resume operation NOTE A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired Air conditioner seems to run too much The current air conditioner replaced an older model The use of more efficient components may cause the air conditioner to run longer than an older model but the total energy...

Page 13: ...o a cooler setting by pressing the minus button to reduce the temperature Set the Fan Speed control to the highest setting Water drips from cabinet into your house The air conditioner is not properly leveled The air conditioner should slope slightly downward toward the outside Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage See the Installation In...

Page 14: ...For any questions or Technical Support Please Call Customer Service 1 844 801 8880 ...

Reviews: