20
INSTALLATION MANUAL---Installation of the Indoor unit
Note : Keep the drain pipe down towards the direction
of the wall hole, otherwise leakage may occur.
Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the minim-
um space required around the units.
Install the indoor unit in the room to be air
avoiding in corridors or communal areas.
conditioned
Install the indoor unit at a height of at least 8 ft
(2.5m) from the ground.
To install, proceed as follows:
1. Decide where to drill the hole in the wall for the pip-
ing ( if necessary ) according to the position of the
mounting plate;
2. Install a flexible flange through the hole in the wall to
keep the latter intact and clean.
The hole must slope downwards towards the exterior.
Note : The shape of the mounting plate may be different
from the one above, but installation method is similar .
Indoors
Outdoors
1. Lift up the front panel.
2. Take off the cover as indicated in the piciure ( by
removing a screw or by breaking the hooks).
3. For the electrical connections, see the circuit diagram
on the electrical cover.
4. Connect the cable to the wiring terminal by following
the numbering, Use wire size suitable to the electric
power input (see name plate on the unit) and accord-
ing to all current national safety code requirements.
5. The cable connecting the outdoor and indoor units
must be suitable for outdoor use.
6. The plug must be accessible also after the appliance
has been installed so that it can be pulled out if nece-
ssary.
7. An efficient earth connection must be ensured.
8. If the power cable is damaged, it must be replaced by
an authorised Service Centre.
Front panel
Terminal block cover
wiring diagram
Note:The cable wires has been connected to the main
PCB of indoor unit by manufacturer according to the
model without terminal block.
Installation of the mounting plate
Drilling a hole in the wall for the piping
Electrical connections---Indoor unit
1. By using a level, put the mounting plate in a perfect
square position vertically and horizontally.
2. Drill 1.3 inch (32 mm) deep holes in the wall to
fix the plate;
3. Insert the plastic anchors into the hole;
4. Fix the mounting plate by using the provided tapping
screws;
5. Check that the mounting plate is correctly fixed;
0.2
(5mm)