GRID REMOVAL:

Remove the coupling cover assembly. Insert a rod or screw
driver into the open end loop of the tapered grid. Use the teeth
on the coupling hub as a support to gradually and gently pry
off the grid, proceeding alternately from side to side.

Figure 7

Table 1

Form 17200

12/4/96

Printed in U.S.A.

INSTALLATION AND ALIGNMENT VALUES

SIZE

MAXIMUM RECOMMENDED

MISALIGNMENT LIMITS

GAP

(IN.)

COVER

BOLT

TORQUE

(LB-IN.)

ALLOWABLE

MAXIMUM

SPEED

(RPM)

LUBE/

GREASE

WEIGHT

(LB.)

OFFSET

(IN.)

ANGULAR

(IN.)

1020

0.006

0.003

0.125

100

4,500

0.07

1030

0.006

0.003

0.125

100

4,500

0.07

1040

0.006

0.003

0.125

100

4,500

0.11

1050

0.008

0.004

0.125

200

4,500

0.11

1060

0.008

0.005

0.125

200

4,350

0.20

1070

0.008

0.005

0.125

200

4,125

0.24

1080

0.008

0.006

0.125

200

3,600

0.37

1090

0.008

0.007

0.125

200

3,600

0.55

1100

0.010

0.008

0.188

260

2,440

0.95

1110

0.010

0.009

0.188

260

2,250

1.12

1120

0.011

0.010

0.250

650

2,025

1.61

1130

0.011

0.012

0.250

650

1,800

2.00

1140

0.011

0.013

0.250

650

1,650

2.50

KOP-FLEX, INC.
EMERSON POWER TRANSMISSION
P. O. Box 1696
Baltimore, MD 21203-1696

Summary of Contents for Kop-Flex KOP-GRID H Series

Page 1: ...ained and that the lubricant is free of contaminates In an average industrial application the coupling should be checked for lubricant contamination and replenished with the proper volume every twelve months Conditions such as very slow speed reversing drives high heat and severe environ ments may require more frequent lubrication RECOMMENDED LUBRICANT KOP FLEX KSG Coupling Grease This grease is s...

Page 2: ...alue should not exceed the angular limit specified inTable 1 Important Safety Instructions Before start up for reasons of safety and to extend shaft coupling life follow these requirements 1 Coupling guards protect personnel ALL COUPLINGS MUST BE COVERED WITH A GUARD AS PER OSHA REQUIREMENTS 2 Recheck alignment after all foundation bolts and mechani cal connections are tightened 3 Make sure all fa...

Page 3: ...egment s open ends are on the same side Figure 5 Figure 6 5 COVER INSTALLATION LUBRICATION Pack the grid with additional KSG grease or the equivalent and wipe off the excess flush with the top of the grid Slide seals over the hub and adjust to line up with the cover seal grooves Place gaskets on both flanges of the lower cover and install top cover Align cover match marks on the same side For vert...

Page 4: ...OVER BOLT TORQUE LB IN ALLOWABLE MAXIMUM SPEED RPM LUBE GREASE WEIGHT LB OFFSET IN ANGULAR IN 1020 0 006 0 003 0 125 100 4 500 0 07 1030 0 006 0 003 0 125 100 4 500 0 07 1040 0 006 0 003 0 125 100 4 500 0 11 1050 0 008 0 004 0 125 200 4 500 0 11 1060 0 008 0 005 0 125 200 4 350 0 20 1070 0 008 0 005 0 125 200 4 125 0 24 1080 0 008 0 006 0 125 200 3 600 0 37 1090 0 008 0 007 0 125 200 3 600 0 55 11...

Reviews: