EMC-PAC User Guide 

 

 

 

- 9 - 

Warranty 

SHIPPING AND LIABILITY 

Please verify that the shipment is received in good order ASAP. 

EmerCom Technologies Inc. warrants parts and labor on all equipment of its own manufacture 
for a period of 10 years from the date of shipment but cannot be held liable for any loss or 
damage resulting from causes beyond their reasonable control. Any abuse, vandalism, 
alteration or misuse of these products for purposes or in a manner other than that for which they 
were manufactured will void the warranty. 

Please return defective products prepaid to your nearest service center after first calling 
1-604-589-3899 (or toll-free 1-844-363-7266) for a Return Authorization (RMA) number. Please 
provide: 

  Model number 

  Problem or fault description 

  Name of the person requesting the RMA, phone number and shipping address 

Please reference the RMA number clearly on all packaging and paperwork. 

Note:  Statistically, more field problems are caused by wiring, connection, power supply or 
installation issues rather than the devices themselves.  Please have your field staff call us from 
site before concluding that an EmerCom product needs to be returned, to offer you the 
assistance to resolve the problem most conveniently over the phone. 

EmerCom Technologies Inc. shall not be liable for any loss or damage resulting from causes 
beyond its reasonable control and in no event whatsoever shall we be liable for consequential 
damages resulting in personal injuries, property damage or economic loss to any party. 

 

 

Summary of Contents for EMC-60

Page 1: ...EMC PAC USER GUIDE Power and Alarm Consolidator...

Page 2: ...to BAT 2 3 4 Connect first station phone line alarm STN 1 to PLM on EMC 60 phone Connect additional stations as required STN X to PLM on EMC 60 phon 1 Troubleshoot alarms if any POWER ON for normal o...

Page 3: ...Specifications 8 Ordering 8 Warranty 9 About the EMC PAC Power Alarm Consolidator Board Key Features Uninterruptable power supply UPS for up to two EMC ALRM boards Consolidates the phone line alarm o...

Page 4: ...4 STN 3 STN 2 STN 1 PWR IN BAT PWR OUT GRP A GRP B PWR CALL CALL LED LED TEL TEL PLM PLM LED2 AUX MIC SPKR ALARM BATT SD Card 1 4 7 2 5 8 0 3 6 9 LINE TEST CANCEL REPLAY ENTER PROGM SPKR SPKR ALARM S...

Page 5: ...uide 5 EMC ALRM and EMC PAC Low Rise Layout Group B Group A Telco Phone Line EMC PAC 110 V AC EMC 60 Hands free phones in elevator cabs EMC ALRM EMC ALRM Shielded Twisted Pair STP battery 110V Supply...

Page 6: ...ed by reading the name of the status LED or by looking up the problem in the troubleshooting section Additional red LEDs exist at each STN and each GROUP terminal to aid the technician with the differ...

Page 7: ...load on PWR OUT Contact Support 1 844 363 7266 Dimensions 16 5 24VAC 16 28VDC 12V SLA 1200mAh fuse 1A fast MAINS BYPASS BUZ EmerCom Technologies Inc 1 844 363 7266 CONNECT TO EMC ALRM CON NECT TO EMC...

Page 8: ...end of the traveling cable Output Power 12Vdc typical 200mA max Input Power 16 5 24Vac 16 28Vdc Battery Type Sealed Lead Acid Rated Voltage 12V Capacity 1 2AH Terminals 0 187 spade Operating Range 0...

Page 9: ...7266 for a Return Authorization RMA number Please provide Model number Problem or fault description Name of the person requesting the RMA phone number and shipping address Please reference the RMA nu...

Page 10: ...EMC PAC User Guide 10 Rev 1p0a...

Reviews: