Emelson EMLCLE10SLGB-K Owners And Installation Manual Download Page 4

- 3 - 

Attention

This product’s safety function is concluded by lab tests, it will  be influenced by the  environment in the 
practical use. Please respect use of this device and keep maintained in a good condition. 

Model instruction 

Fig.1(b) 10KM 

Summary of Contents for EMLCLE10SLGB-K

Page 1: ...english Thanks for choossing our product Please read carefully this manual before using the product OWNER AND INSTALLATION MANUAL CLOSED CHAMBER GAS WATER HEATER SL EMLCLE10SLGB K ...

Page 2: ...e installing and operating Keep it for future reference Contents Special Advice1 2 Features 2 Model instruction 3 Parts Name 4 Dimensions 5 Specifications 7 Installation 8 Using methods 11 Safety attention 13 Daily maintenance 15 Error code 16 Circuit Diagram 17 Trouble Shooting 18 ...

Page 3: ...w out only after opening the water supply tap Convenient adjustment Water volume and firepower adjusted independently very convenient to regulate the water temperature High efficiency energy saving Both the burner and heat exchanger are designed by using international advanced combustion theory with the feature of high efficiency and quality combustion performance Low water pressure ignition In or...

Page 4: ... product s safety function is concluded by lab tests it will be influenced by the environment in the practical use Please respect use of this device and keep maintained in a good condition Model instruction Fig 1 b 10KM ...

Page 5: ... 4 DIMENSION All the figures for reference see the product for real appearance ...

Page 6: ...sulation grade Class I Electrical and water protection IPX4D IPX0 when installed as type B23 Ignition method Water control automatic pulse ignition Temperature control method Gas proportional valve automatic control Destination country AT BE CH DE DK ES FI FR GB GR IE IT NL PT NO SE Pipe joint Gas inlet G1 2 or G3 4 Water inlet G1 2 Water outlet G1 2 Exhaust pipe Φ100 external Φ60 internal WARNING...

Page 7: ...ime of the heater or prevent normal working Fig 5 Do not to install the flue of the heater through the wall whose window can be opened because the waste gases may flow back into indoors if the window is opened during using operation Fig 6 Don t install the heater above the gas stoves or other heat sources Fig 7 The power of the heater is 230V 50Hz AC the power socket must have a reliable ground wi...

Page 8: ...gas to the outdoor according to the strictest requirements It s not allowed to use the gas water heater without operating the flue correctly Installation position of flue terminal protruding through wall The minimum flue length is 650mm and the maximum flue length is 3000mm with one elbow Fig 12 Install the flue after the heater body is fixed First put the fixed flue through the hole in the wall t...

Page 9: ...a leak NOTE No substance other than air carbon dioxide or nitrogen can be introduced into the gas piping NOTE If you have a leak shut off the gas After verifying the leak tighten appropriate fittings to stop leak Turn the gas on and check again with a soapy solution Never test for gas leaks using a match or flame Cold water inlet When facing the heater the cold water inlet is on your right and the...

Page 10: ...ermanent dedicated ventilation directly to the outside Warning The surface of the B23 flue is very hot must use insulating refractory between the flue and combustible parts of the wall And the minimum thickness of the refractory insulation material must not less than 20mm The minimum size of ventilation must not less than 200cm2 B23 flue installed as follow pic Using methods FOR YOUR SAFETY READ B...

Page 11: ...e When the valve is open while the switch is in off position the heater doesn t work only cold water flows out if hot water is needed press the switch to on position Close down the water valve the heater stops working but the fan will continue blowing the chamber for several seconds If you don t turn off the power then next time when you open the water valve the heater will work according to the w...

Page 12: ... is out after use and do not forget to turn off the gas valve Fig 19 and power Always check the gas connectors for gas leakage with soapsuds If any gas leakage is detected open the room windows and doors At that moment do not ignite or operate the switch of electric appliances or plugs because the flame or electric spark can result in explosive accidents Fig 20 Heaters must use the gas type which ...

Page 13: ...y discharge the combustion bi products to the outdoors and intake the combustion air from outdoors so as to keep the indoors air fresh and prevent incomplete combustion Otherwise it will cause danger or even death Too low or too high gas pressure leads to abnormal combustion At that moment stop using the water heater and get in contact with a service engineer Dust and accelerated carbon would bloc...

Page 14: ...abnormal conditions Keep the cover of the water heater clean This product uses water pressure to open the channels When the water pressure is lower than 0 2bar the heater cannot be ignited The drain valve is dripping When the water pressure is too high the drain valve will release the water so as to reduce the pressure to protect the heater When the heater is supplying hot water to several points ...

Page 15: ... other parts of water heater 6 After Cleaning put the front cover back Error Codes Error Code Description Reasons Repair E0 Inlet water temperature sensor Possible short in sensor may need replacement of sensor check wire to water temperature sensor it may be disconnected E1 Ignition fail or lost flame Hardware error in detecting the flame feedback No flame detection after ignition 6 seconds Lost ...

Page 16: ...thermostat open Controller board error F2 Gas Valve driver circuit error Controller board error F3 The power of Gas Valve error Controller board error F4 Main Valve control circuit error Controller board error F5 Proportional Valve driver circuit error Controller board error F6 AD converter error Controller board error F7 Setting Switch error Controller board error ...

Page 17: ... 16 Circuit diagram ...

Page 18: ...n Abnormal pressure high Contact repairer low Water valve not open completely Open it completely Insufficient fresh air Improve ventilation till fresh air is enough Too high outside wind pressure C type Stop using temporarily Frozen Use after melt Insufficient water pressure Ask repairer to check water pressure Wrong temperature Regulation Turn the temperature knob properly Power failure or not sw...

Page 19: ...arance No Names Quantity 1 Water heater 1 set 2 Gas inlet hose 1 piece 3 Water inlet hose 1 kit 4 Expansion bolts M6 1 kit 5 Mounting screws 4 piece 6 Customer advice 1 piece 7 Self tapping screws 4 pieces 8 Flue is packed in another carton 1 kit ...

Page 20: ...C Industria nº 13 Polígono Industrial El Pedregar 08160 Montmeló Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info geinal com ...