- 9 -
●
Hot water outlet
Use a flexible or rigid pipe to connect with the sprayer without valve. If a valve or switch is connected to
the sprayer, the outlet pipe shall not use heat and pressure unendurable material such as plastics,
aluminum pipes, so as to avoid the pipe from breaking and scalding the user.
■
Convert to B23 type:
▲
Different kits convert to B23 type.
Flue Type
Lable
Air inlet adaptor
Flue length(mm)
C13
YG28
Original lable
Not fit
650-3000
B23
YG60
Add B23 lable
Fit
650-3000
▲
Warning: B23 appliances should only be installed in the open air or in a room which is separated
from habituated rooms and supplied with appropriate permanent dedicated ventilation directly to the
outside.
▲ Warning: The surface of the B23 flue is very hot, must use insulating refractory between the flue
and combustible parts of the wall.
And the minimum thickness of the refractory insulation material
must not less than 20mm.
▲
The minimum size of ventilation must not less than 200cm2.
▲
B23 flue installed as follow pic.
Using methods
FOR YOUR SAFETY READ BEFORE OPERATING YOUR HOT WATER HEATER
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
For type C
1. Preparation before ignition
●
Make sure that the gas used is in accordance with the gas stipulated in the label.
●
Insert the plug, and then switch on the power.
●
Open the water valve, turn the water valve to get suitable water volume if necessary.