15
Caution!
Take care that the “MFKTS” – multifunction valve on the top of the reactor (inside LOTUS)
is adjusted with a counter-pressure of minimum 1 bar!
Dilution water connection [ A ]
Inside LOTUS is a storage tank [ 8 ] for the dilution water. The automatic refill is controlled by a float valve [ 9 ].
The float valve has to be connected to the water line with a 4x6 mm PE-hose (2 m included in the delivery
scope).
Notice:
•
In case the pressure in the water line is more than 5 bar a pressure regulator valve in the re-
filling line is required. The adjusting range should be 0.3 – 4 bar.
•
For a proper function of the pressure regulator valve and the float valve inside the tank a pro-
tection filter like a ”
NFIL/60“
is recommended.
Overflow connection [ C ] for the dilution water storage tank
The dilution water storage tank [ 8 ] has a overflow connection with a 20 mm PVC adhesive connection.
The overflow should be connected to a floor drain.
Summary of Contents for LOTUS MINI