“Set-Point pH” (on/off) mode ALKALI
This mode is valid for any “Digital” output available. On/Off mode set the CONTROLLER to operate using two set
values that enable or disable the pH pump. To use this mode choose “Working Mode”. Tap on it.
ON/OFF mode while dosing ALKALI
Set pH value at 7.00 OFF and 6.90 ON. Set Pulse Speed per minute (strokes per minute) based on dosing device capabilities.
CONTROLLER will leave the pH pump active until reading value will increase up to 7.00pH.
At 7.00pH the pH pump will be disabled until reading value will decrease under 6.90pH.
Tap on main function to enable / disable
Tap on value to change them according to preferences
Tap on Out to choose between any output available
6.90 7.00
ON
OFF
7
6.90