l
If the battery is good, but the system will not boot, or if the battery is failing to
charge, contact EMC Data Domain Technical Support.
Enable administrative communication
Note
See the
for the locations of the onboard interfaces.
1. Connect an administrative console to the serial port on the back panel of the system.
2. Launch a terminal emulation program from your computer and configure the following
communication settings:
Setting
Value
Baud rate
9600
Data bits
8
Stop bits
1
Parity
None
Flow control
None
Emulation
VT-100
3. Log into the CLI as the
sysadmin
user.
localhost.localdomain login:
sysadmin
Password: <system_serial_number>
4. Enter the default password, which is the system serial number (SSN). The SSN is on
the SSN pull-out tag at the top, left side of the back panel of the system, shown
below. See also
Onboard interfaces and LEDs on page 9
for the location.
Figure 23 SSN pull-out tag
End User License Agreement (EULA)
The first time you log in to the system, the End User License Agreement (EULA) displays.
At the end of the EULA, you are prompted for acceptance: