Cabling a CX700
2-17
Setting Up and Starting a CX700 System
Figure 2-11
Sample CX700 and DAE Cabling — Two Cabinets with Two Loops
Note that for increased clarity and ease of maintenance, the configuration in
Figure 2-11 segregates the loops into the separate cabinets.
EMC1989
EA7/Loop 0
EA7/Loop 1
EA5/Loop 0
EA5/Loop 1
EA3/Loop 0
EA3/Loop 1
EA1/Loop 0
EA1/Loop 1
1-Meter
Cable
5- or 10-Meter Cable
SPS B
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
SPS A
Loop 1
Loop 1
Loop 1
Loop 1
Loop 1
Loop 1
Loop 1
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
Loop 0
Loop 1
Loop 1
Loop 1
Loop 1
Loop 1
Loop 1
Loop 1
LCC A
LCC B
SP B
SP A
EA6/Loop 0
EA6/Loop 1
EA4/Loop 0
EA4/Loop 1
EA2/Loop 0
EA2/Loop 1
EA0/Loop 0
EA0/Loop 1
LCC B
LCC A