Cabling a CX700
2-7
Setting Up and Starting a CX700 System
Set EAs for DAE2P disk enclosures after the system is powered on.
See Figure 2-2 and Figures 2-9 through 2-12 as necessary.
Figure 2-2
Enclosure Address (EA) Switch on a DAE2
Cabling a CX700
After a CX700 is installed in a rack or cabinet, you can connect all
necessary cables. You will connect
◆
ac line cords between power supplies and SPS units
◆
Serial connections between storage processors and SPS units
◆
Serial connections between storage processors and dc power
supplies
◆
Each SP to the front-end (FE) external environment (server or
switch)
◆
Each SP’s first back end (BE 0) to a DAE
◆
Each SP’s BE 1 to a second DAE, if present
◆
Optional third and fourth back loops to additional DAEs
◆
Multiple DAEs together
For details on installing a CX700 and DAEs in a cabinet, see the
EMC Rails
and Enclosures (CX-Series Storage Systems) Field Installation Guide
.
EMC2769
Enclosure
Address
Switch
+
_
0