49
Serial/Ethernet/USB Communication (SCOM) Interface - MCC Commands
IND100084-22
Function
Data
Description
GEV2
GEV1
Differences
Color Temperature Select
0xB3,
n | ’r’ | ’R’ | ’?’
Set Color Temperature = value /
/ reset / query
Color temperature
'0' - ‘9’’3’’0’’0’ - 9300K
'1' - ‘8’’0’’0’’0’ - 8000K (default)
'2' - ‘6’’5’’0’’0’ - 6500K
'3' - ‘U’’S’’E’’R’ - USER
Color temperature
'0' - ‘9’’3’’0’’0’ - 9300K
'1' - ‘8’’0’’0’’0’ - 8000K (default)
'2' - ‘6’’5’’0’’0’ - 6500K
'3' - ‘U’’S’’E’’R’ - USER
Same as GEV1
Red Level for Selected Color
Temperature
0xB4,
nn | ‘+’ | ‘-’ | ’r’ | ’R’ | ’?’
Set Red Level = value /
increment / decrement / reset / query
Red Gain
Range=‘0’’0’~’2’’5’’5’
Default = ‘1’’2’’8’
Red Gain
Range=‘0’’0’~’6''4'
Default = ‘3''2'
Value Range changed from 0-32 to 0-128
Green Level for Selected Color
Temperature
0xB5,
nn | ‘+’ | ‘-’ | ’r’ | ’R’ | ’?’
Set Green Level = value /
increment / decrement / reset / query
Green Gain
Range=‘0’’0’~’2’’5’’5’
Default = ‘1’’2’’8’
Green Gain
Range=‘0’’0’~’6''4'
Default = ‘3''2'
Value Range changed from 0-32 to 0-128
Blue Level for Selected Color
Temperature
0xB6,
nn | ‘+’ | ‘-’ | ’r’ | ’R’ | ’?’
Set Blue Level = value /
increment / decrement / reset / query
Blue Gain
Range=‘0’’0’~’2’’5’’5’
Default = ‘1’’2’’8’
Blue Gain
Range=‘0’’0’~’6''4'
Default = ‘3''2'
Value Range changed from 0-32 to 0-128
Graphic horizontal resolution
enquiry
0xB7
Horizontal resolution (in pixels) in 3
digital hex number
‘nnn’ = horizontal resolution
‘nnn’ = horizontal resolution
Same as GEV1
Graphic vertical
resolution enquiry
0xB8
Vertical resolution (in pixels) in 3 digital
hex number
'nnn' = vertical resolution
‘nnn’ = vertical resolution
Same as GEV1
Graphic horizontal sync frequency
0xB9
Horizontal sync frequency (in units of
100Hz) in 3 digit hex number
'nnn' = horizontal frequency
'nnn' = horizontal frequency
Same as GEV1
Graphic vertical sync frequency
0xBA
Vertical sync frequency (in units of
0.1Hz) in 3 digit hex number and 1char
'nnnc' = vertical frequency
c = 'i' or 'p' Interlace or progressive
‘nnnc’ = vertical frequency
c = ‘i’ or ‘p’ Interlace or progressive
Same as GEV1
Set Address RS
0xBB,
n|'?'
Set Address RS = value
Address RS
Range -'0'~'F'
Address RS
Range -‘0’~’F’
Same as GEV1
Set IP address
0xBC,
n.n.n.n | 'a' | 'A'|'?'
Set fix IP and IP = n.n.n.n (each n range
is from '0' to '2''5''5') / Set auto IP, after
send this command do AC on/off
'0' - fail
'1' - success
‘0’ - fail
‘1’ - success
Same as GEV1
Auto Position
0xC3
Auto set image position
'0' - fail
'1' - success
‘0’ - fail
‘1’ - success
Same as GEV1
Auto Color Balance
0xC5
Auto set image Color balance
'0' - fail
'1' - success
‘0’ - fail
‘1’ - success
Same as GEV1
Out Door mode
0xCA,
'0' | '1' | 'R' | 'r' | '?'
Set the key is delay 5 second/ reset /
query
'0' - OFF (default)
'1' - ON
'0' - OFF (default)
'1' - ON
Same as GEV1
Burn in
0xCC,
'0' | '1' | 'R' | 'r' | '?'
Set burn in mode / reset / query
'0' - normal mode (default)
'1' - burn in mode
'0' - normal mode (default)
'1' - burn in mode
Same as GEV1
Test pattern
0xCD,
'0' | '1'
Display test pattern / Go to default state
'0' - normal display
'1' - display built in test pattern
'0' - normal display
'1' - display built in test pattern
Same as GEV1
OSD Factory Default
0xCE
Reset all parameters defined in OSD
menu to default factory values
'0' - fail
'1' - success
'0' - fail
'1' - success
Same as GEV1
Saving the user default
0xD7,
n
Saving all parameter to user default
value (n = '1' to '5' correspond to User1
to User5)
'0' - fail
'1' - success
'0' - fail
'1' - success
Same as GEV1
Loading the user default
0xD8,
n
Loading all parameter to user default
value (n = '1' to '5' correspond to User1
to Uesr5, and '0' is read Default)
'0' - fail
'1' - success
'0' - fail
'1' - success
Same as GEV1