background image

7

•  The ‘Always On’ sockets are recommended for use with Audio Visual 

(AV) equipment that requires constant power for timers, program guide 

and recording features (e.g. DVR, PVR, VCR, Cable, Digital TV Receivers, 

hard drives or bedside alarms). This will ensure constant power is not 

interrupted to these devices.

•  The ‘Power Saver’ sockets are recommended for Audio Visual (AV) equipment 

that can be automatically switched off (e.g. Televisions, amplifiers, stereos, 

speakers, some game consoles, DVDs, CDs, Blu-ray players, lamps).

•  The LED monitoring light indicates that power is available at the 'Power 

Saver' sockets of the Embertec Emberstrip™ AV+.

•  Overload protection circuit breaker re-set button.

•  3 pins for use with standard North American wall sockets.

•  Infrared SmartSensor activates the ‘Power Saver’ sockets, monitors activity 

and is also used to set the Active Powerdown™. Comes with a 3 meter/9ft 

cable, LED light and integrated push button control.

•  The 'Surge Protected' light should be on. If this light turns off or is dim, 

you may have a ground-wiring problem in your home and you should 

contact an electrician to properly ground the outlet.

•  The 'Power Saver Sockets On' light shows the state of the 'Power Saver' 

sockets. When the light is on, the 'Power Saver' sockets are powered; if the 

light is off, the 'Power Saver' sockets are not powered.

Summary of Contents for Emberstrip AV+

Page 1: ...Instruction Booklet Embertec Emberstrip AV with Active Powerdown EBUSAV ET 01 PATENTS GRANTED AND PATENTS PENDING...

Page 2: ...t Close to your television is the best position and within normal operation of your existing remote control s 5 For coaxial cable surge protection a Connect your DSS receiver TV VCR or cable box to th...

Page 3: ...into the Always On sockets if needed or with the Power Saver if only needed when your AV system is being used SmartSensor Console Speakers Cable Console Set Top Box Amplifier Blu ray or DVD Player TV...

Page 4: ...red Turning OFF your AV Equipment Simply turn your equipment off in the normal way Once the Audio Visual AV components have been switched off the Embertec Emberstrip AV will remove power from the Powe...

Page 5: ...5 Contents Quick Connection Guide p2 What you need to know p8 What is MusicMode p12 Fast Facts p13 Embertec Emberstrip AV p14 Specifications Troubleshooting Guide p15 Warranty p16...

Page 6: ...bertec Emberstrip AV 2 SmartSensor 3 On Off Power Saver sockets indicator light 4 Power Saver sockets 5 Always On sockets 6 Reset Button 7 Coax In 8 Coax Out Your Embertec Emberstrip AV 2 1 3 7 8 6 5...

Page 7: ...ailable at the Power Saver sockets of the Embertec Emberstrip AV Overload protection circuit breaker re set button 3 pins for use with standard North American wall sockets Infrared SmartSensor activat...

Page 8: ...ipping out Ensure cords plugged into the Embertec Emberstrip AV remain tangle free It is recommended to regularly inspect the Embertec Emberstrip AV for damage The Embertec Emberstrip AV must not be u...

Page 9: ...ich can be permanently set to 2 hours or temporarily 8 hours MusicMode When will Active Powerdown Switch the Audio Visual AV Equipment off If your Embertec Emberstrip AV detects that your Audio Visual...

Page 10: ...such as DVD recorders pay TV and PVR units set top boxes hard drives or digital receivers Certain home theater projectors that require a cool down period including rear projection televisions Power S...

Page 11: ...e instructions to change Active Powerdown to 2 hours this may be preferred for longer movies or programs where remote control activity is less frequent Music Mode 8 hours Once one second then release...

Page 12: ...period of time The Embertec Emberstrip AV will revert to its previous setting of 1 or 2 hours after the 8 hour period or after a power down has occurred Remember 1 In this mode your system will stay...

Page 13: ...ain Once reset use any remote control to activate power to the Power Saver sockets Connect one device at a time If any of the devices cause the safety device to trip again then get the offending devic...

Page 14: ...erature storage 4 0 F to 185 0 F 20 0 C to 85 0 C Humidity operating 95 RH at 1220 F 50 0 C Protection Surge Standards Compliance ANSI UL STD 1449 3rd Edition General Component Surge Rating Total 2 08...

Page 15: ...LED on the main body of the Embertec Emberstrip AV is flashing but my SmartSensor LED does not work when plugged in and powered on Please check your SmartSensor connection to the Embertec Emberstrip A...

Page 16: ...not apply to you You will be responsible for any shipping or other transportation costs incurred in connection with returning the defective product to us How do you request service under this limited...

Page 17: ...rrence After each Occurrence the Embertec Emberstrip must be replaced Any damaged equipment that has been disposed before we have examined the equipment at the site where the damage occurred or notifi...

Page 18: ...ow unprotected if this situation is undesirable for the application follow the manufacturer s instruction for replacing the device Caution for tv port part Note to catv system installer Attention sur...

Page 19: ...19...