L
15
18
2
16
13
6
10
14
11
7
5
9
12
1
8
3
4
28
20
19
LP Conversion
Items
21
22
23
24
25
17
26
27
(18,24,30)DBNL - 60 PARTS
Page 1: ...your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be...
Page 2: ...s manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its con trols can be dangerous 1 This appliance as supplied is only for use w...
Page 3: ...his log set to cook food or burn paper or other objects 13 Logsetbecomesveryhotwheninuse Keep children and adults away from hot surface to avoid burns or clothing ignition Log set will remain hot for...
Page 4: ...ose paint by a quali ed chimneycleaner Creosotewillignite if highly heated Adirty chi mney uemaycreateanddistribute soot within the house Inspect chimney ue for damage NOTICE Installation service and...
Page 5: ...taching Damper Clamp CONNECTING TO GAS SUPPLY WARNING A quali ed service person must local codes connect log set to gas supply Follow all Installation Items Needed Before installing log set make sure...
Page 6: ...from gas supply piping system 2 Cap off open end of gas pipe where equipment shut off valve was connected 3 Pressurize supply piping system by either using com pressed air or opening main gas valve l...
Page 7: ...from Natural Gas to LP gas If connecting to a Propane gas system regulator must be switched prior to use Follow the the steps below to select Propane gas 1 Carefully remove the logs from the burner as...
Page 8: ...s 4 When burner is tested and Leak free Observe individual tongues of ame on burner from ports Note Make sure that all ports are clear and pro ducing ame evenly across burner If any ports ap pear bloc...
Page 9: ...G PLACEMENT MODEL BRO18DBNL 60 Place log 1 onto back left area of the grate perpendicular to log 2 Place Y shaped log 4 onto left of the grate ahead of raised area Place log 3 at the front right of th...
Page 10: ...raised area Log Identification Back Log Stand Offs in place 1 2 3 4 6 7 8 9 on the grate finger left of center Place log 3 onto back left area of the grate perpendicular to log 1 Place log 4 at the fr...
Page 11: ...LOG PLACEMENT MODEL BRO24DBNL 60 Cont Place the two small logs 7 and 8 in front of the grate as shown 11...
Page 12: ...the grate Place shorter back log 2 onto Back Log Stand Offs in place Back Log Stand Offs 1 2 3 4 5 6 Place Cross Log 3 at the left side Place Cross Log 4 at the center Place Cross Log 5 at the right...
Page 13: ...Log 7 atop the center Left 4 to the center right 5 logs 1 2 3 4 5 6 Log Identification MO24NG Follow the first five steps from MO18NG on previous page Place Cross Log 4 at the center right Place Y Sha...
Page 14: ...grate Place shorter back log 2 onto raised area of the grate 1 2 3 Log Identification Back Log Stand Offs in place Place Cross Log 3 at the left side Place Cross Log 4 at the right side Place Cross Lo...
Page 15: ...he grate Place shorter back log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 4 at the center left Place Cross Log...
Page 16: ...LOG PLACEMENT MODEL SH24DBNL 60 cont Place cross log 7 atop cross log 6 and to front center as shown 16...
Page 17: ...ack log 3 onto raised area of the grate Log Identification Back Log Stand Offs in place 1 2 Place left front log 2 onto front area of the grate 3 4 5 6 Place Cross Log 4 at the center left Place Y sha...
Page 18: ...DEL CS30DBNL 60 Cont Place Cross Log 8 at the top center across logs 5 and 7 Place Cross Log 7 at the center right Place log 8 in front of the set on the fireplace floor Make sure it is in front of th...
Page 19: ...TING INSTRUCTION 1 STOP Read the safety information on the left side of this page 2 Make sure equipment shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF position 4 Wai...
Page 20: ...t hand side of the burner The thermocouple should be fully enveloped in the ame The ame should not be lifting off of the thermocouple element If your pilot assembly does not meet these require ments T...
Page 21: ...ng down con trol knob Repeat igniting op eration until air is removed 5 6 Clean pilot see Cleaning and Maintenance above or replace pilot assembly Check replace gas regulator Pilot lights but ame goes...
Page 22: ...REMEDY TROUBLESHOOTING Continued Delayed ignition burner 1 Pilot angle needs adjusting 2 Wrong pilot ori ce for gas type 1 Adjust pilot angle for best ame contact with burner pan 2 Replace pilot ori c...
Page 23: ...L 15 18 2 16 13 6 10 14 11 7 5 9 12 1 8 3 4 28 20 19 LP Conversion Items 21 22 23 19 23 24 25 5 17 26 27 18 24 30 DBNL 60 PARTS...
Page 24: ...Vented 22 SPSCJ00106A Standoff Back Log 23 Burner Spacer RMH 120 00420 RMH 120 PBAGA Pilot Bracket 24 RMH 120 00574 Damper Clamp RMH 120 00100 25 26 27 1 0 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RMH...
Page 25: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...
Page 26: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...
Page 27: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...
Page 28: ...n misuse abuse hostile environments or improper installation repair or alteration acts of God such as fire flood hurricanes and tornadoes gas cylinders propane tanks or other fuel deliverysystems incl...