9
PC Control Software
The programmer can be controlled using:
•
EQTools (as standard)
•
ISP-PRO (chargeable upgrade)
•
Standalone Upload Wizard (chargeable upgrade)
•
ConsoleEDS
Evaluation
version
•
ConsoleEDS PRO (chargeable upgrade)
•
ASCII Text Mode (chargeable upgrade)
2.3
10 PC
requirements
PC running Windows 95 / 98 / 2000 or ME / NT4 / XP
11 Power
Supply
Options
There are 3 possible modes for powering the Programmer /
Target System:
•
Programmer powers Target System
•
Target System powers the Programmer
•
Programmer and Target System are independently
powered
3.0
12 Voltage
range
See specified section
1.5.2
13 Vpp
Voltage
Generator
On Board +12.0V Vpp Voltage Generator
(A12.0V to RESET pin for ATtiny HV programming)
14 DC
Power
Connector
(CON1)
•
DC
Power
Connector
•
2.5 mm Jack Socket – Centre Positive
•
DC Power Lead supplied with programmer – white
stripe is +ve.
1.5.2
15 Programmer
Current
Consumption
This refers to the current consumption of the actual
programmer circuitry. See specified section.
1.5.3
16 Max. current through
programmer
This refers to the maximum current which can be supplied
through the programmer from CON1 (i.e. external power
supply) to the Target System.
Max current = 300 mA.
1.5.3
17 Target
SPI
Frequency
Software SPI algorithm:
•
SLOW SPI: 0 – 490.2 kHz (user selectable)
•
MEDIUM SPI: 0 – 490.2 kHz (user selectable)
( SPI speeds are estimations only due to uneven mark/space
ratio and non-continuous waveforms)
Hardware SPI algorithm (requires firmware 3.04 or
greater):
•
SLOW SPI: 115.2 kHz to 921.6 kHz (user selectable)
•
FAST SPI: 115.2 kHz to 921.6 kHz (user selectable)
18 Target UART Speed
This is the Communications Speed (BAUD rate) from the
programmer to the Target Device when communicating via a
Boot Loader. The BAUD rate is configurable from 1,200 to 115
kBaud. This settings is completely independent from the BAUD
rate settings for the PC communicating with the programmer.
4.0