P19 TROUBLE SHOOTING
12. TROUBLE SHOOTING
Possible Solution
Trouble
Disconnect the power cord from the electrical outlet, disassemble the lamp and
verify if the lamp connector is fixed firmly in place.
Verify if the electric cable is connected into an electrified circuit. Test the electrical
circuit.
Verify that the electrical outlet where the UV-C System is plugged into has the
proper voltage and the cable is securely plugged into the outlet.
The lamp has burned out. Replace the UV lamp.
Check the chemical balance of the pool.
Check the UV-C system to make sure it is on.
Run the UV-C system and the circulation pump longer. If the UV system is operated
by a timer, increase a number of working hours.
Check all connections and sealing rings, especially those near to the UV lamp and
the quartz glass.
Check the screws on the installation, and pay attention to those vibration points
Check all connections and sealing rings, make sure that all connections are threaded
properly.
Check the quartz glass if it is broken or damaged.
Consider replacing the UV lamp. After 4500 hours of operation, the lamp efficiency
drops up to 80%. This is normal for all low- pressure type UV lamps.
Clean the air mesh for O-zone model to ensure air flow is enough.
The electrical unit has burned out. Contact your supplier for the replacement.
Check the timer setting. It can be at “OFF” schedule.
UV-C system failure, possible lamp
disconnection
The UV lamp no longer lit
Pool water is green
UV-C system makes noise when operating
Water is coming out; the UV-C system is
leaking
Make sure you have not connected the device into any power source other than
specified on the unit's label. If you have done so in error, the electrical unit might
have been damaged and should be replaced. Contact your supplier for the
replacement (Not warranted).
INSTALLATION P8
5.3 INSTALLATION OPTIONS
The dark blue transparent end cap and union set is inter changeable for all models, it can be place on either side.
It is necessary to place and tighter the O-ring properly to prevent water leakage when doing relocation. There
are two sets of 1.5” and 2” union which can be fit into imperial and metric pipe.
Transparent end cap with o-ring
Union with O-ring set
1.5” and 2” union
For NT-UV16, NT-UV40, NT-UV40-T, NT-UV75 and NT-UV75-T model Lamp unit, stainless steel lamp body can be
installed in vertical or horizontal orientation.
WARNING:
For NT-UV130F, NT-UV130-TF (130W UV-C Lamp), and NT-UV87-TO (O-zone) only vertical
installation is allowed.
Mounting Options:
Instead on mounting on wall, there are two option of mounting on the ground.
1. Using the mounting base provided.
2. Using a wooden stand (not provided)