ELECTRICAL WIRING-3 PHASE P8
6. ELECTRICAL WIRING-3 PHASE
This power pump demand licensed or certified electrician or qualified
pool installer to ensure there is adequate protection between the pump
motor and mains power supply according to individual countries safety
code.
The pump has power cord with plug attached on the plug, plug it to a
power socket with circuit breaker to isolate the motor from the mains
power for over load protection. The circuit breaker rating should refer to the electrical specification of
individual pump working voltage and power.
The power has to be with a Residual Current Device (RCD) or Ground Fault Circuit Interrupt (GFCI) having a rated
residual operating current not exceeding 30mA.
If the RCD / GFCI device trips, it means there is fault on the power line or motor. Do not use
this pump. Disconnect the pump and have the problem corrected by a qualified ser vice
representative before using. Press the reset button to reset the RDC / GFCI devices after
fixed. It will keeps the circuit shut off and will not reset if the power line problem is not fixed.
It is recommend to test the RCD / GFCI at least once a month.
APS PLASTIC pump operate at 3 phase power line to drive the motor. The latest cable color code is Brown for L1,
Black for L2, Grey for L3, Blue for Neutral and Green & Yellow for Earth.
For old code it is Red for L1, Yellow for L2, Blue for L3, Black for Neutral and Green & Yellow for Earth.
Open the terminal box on the top of the motor, there are six terminals and Ground.
It can be connected in Delta or WYE/STAR connection. The default connection is Delta type.
380VAC 50Hz +10% and -6% electric power is three phase power source voltage range.
Note: This high power pump demand licensed or certified electrician or qualified pool
installer to ensure there is adequate protection between the pump motor and mains power
supply according to individual countries safety code.