background image

1. GERäTEbESchREIbuNG

1. Time adjustment 1 -9 minutes

2. Removable tank

3. Reset

4. Digital time indication 

2

1

3

4

2

3

Parameter

Inner tank dimensions 

Length (mm)

175

Width (mm)

80

Height (mm)

40

Dimensions

Length (mm)

190

Width (mm)

100

Height (mm)

124

Power supply

230V~/ 50 Hz

Protection class

IP 20

Power

max. 50

 

Technical changes reserved.

2. TEchNIcAl DATA

 

3. cONvENTIONAl uSE

The equipment may only be used for the purpose as set forth in the catalogue and in the techni-

cal descriptions which means for ultrasonic cleaning as described in this instruction, and only 

in conjunction with external devices and components which are recommended or approved by 

EMAG AG. Any other use of the equipment is considered to be non conventional. 1In case of non 

conventional use, EMAG AG will not be liable for possible damages and will not warrant for the 

correct and functional work of the components. Part of the conventional use is also the obser-

vance of all information given in the operating manual. To this attention is drawn by the sign on 

the type plate. The correct and safe operation of the equipment implies appropriate transportation, 

storage, installation and assembly as well as careful handling and maintenance.

4. NON cONvENTIONAl uSE

In case of non conventional use of the equipment danger for life and limb as well as danger for 

property may occur. Therefore a non conventional use is prohibited. In case of non conventional use 

EMAG AG will not be liable for possible damages and will not warrant for the correct and functionally 

work of the components. In order to avoid non conventional use of the ultrasound cleaning equip-

ment the following directions are to be considered:

•  The equipment may only be operated with the voltage printed on the type plate on the backside/ 

bottom side of the housing (shockproof socket).

•  No flammable or aggressive chemicals (i.e. acids etc.) must be  used for operation of the equip-

ment. If necessary, use glass container EM 50 DG.

•  During operation do not touch the liquid.

•  In case of transportation damage, don`t connect the equipment with main source.

•  Do not clean creatures (i.e. finger nails, animals etc.) in the equipment.

•  The equipment must only be operated with the correct level of water (water till mark, approx. 1 cm 

below upper brim). This must be controlled if equipment is operated for a longer time.

•  Strongly contaminated goods shall be positioned in the equipment with the contaminated side to 

the bottom – do not staple goods.

•  The goods to be cleaned must not be positioned directly onto the bottom of the tub – use the basket.

•  If the equipment is operated for a longer time, do not stay longer than 4 hours within 1 m distance 

to the equipment.

•  The equipment must only be operated indoor and within a dry environment.

•  It is normal, that the upper brims warm up at longer operation.

5. OPERATING INSTRucTION

The tub is filled with water – with or without cleaning concentrate – and the power connector is 

connected with main source. After power switch is ON cleaning time can be adjusted by the push 

button. By pressing the timer button  cleaning time can be set to wished duration. Permanent opera-

tion should be avoided because by evaporation of the water the equipment may run dry and may be 

damaged. In no case a permanent operation time of 4 hours must be exceeded. The cleaning time to 

be adjusted depends on the contamination level of the goods to be cleaned. If the adjusted cleaning 

time is terminated, the equipment automatically stops the cleaning operation. If start button is again 

pressed the equipment starts again to operate. For stopping equipment operation use RESET switch. 

After termination of the cleaning operation remove cleaned goods from equipment and rinse under 

running water in order to remove possibly still adhered particles. After termination of a cleaning op-

eration – or several cleaning operations – it is recommended – depending on the degree of contami-

nation – to exchange the water. The tub shall be rinsed and dried by a cloth. Please make sure, that 

equipment is operated on dry ground and that no water can penetrate through the slots in the bottom 

of the lower part of the equipment into the equipment.

Advise:

If equipment is filled with new water, please consider a reasonable time for

the outgazing of the water (best cleaning efficiency is achieved with outgazed

water). We recommend an operation of the equipment with water for a couple

of minutes before you insert the goods for cleaning.

6.ExAMPlES fOR ThE clEANING Of GOODS WITh ulTRASOuND

• Eyeglasses, glass frames (please pay attention: Glasses must not be in

  direct contact with the tub bottom).

• Gold and silver jewels, jewelery, emeralds, pearls

• Ink crayons, drawing instruments / - accessories

• Dentures, braces, and many more. 