background image

Shortform

Introduction

dito

 & ditoCo

ntrol

Short manual for 

dito

 & ditoControl Software

(Version 

 1.20 )

Simulation of

Electrostatic

Discharges as per

IEC 61000-4-2,

ISO 10605 and

Related standards

Version:

2.04 / 16.06.2008

the benchmark for emc

Replaces:

2.03 / 14.05.2008

Filename:

Shortform introduction ditocontrol v203.DOC

Printdate:

16.06.08

Summary of Contents for dito

Page 1: ...oControl Software Version 1 20 Simulation of Electrostatic Discharges as per IEC 61000 4 2 ISO 10605 and Related standards Version 2 04 16 06 2008 the benchmark for emc Replaces 2 03 14 05 2008 Filena...

Page 2: ...ontrol 8 3 Technical requirements 9 4 Installation Uninstall 9 4 1 Installation 9 4 2 Remove 9 5 Start ditoControl 10 5 1 Connect the dito simulator via RS232 Interface 11 5 2 Registration 12 5 3 Mode...

Page 3: ...erface 11 Ground Cable Switching On Switching Off ON Push trigger button 9 once OFF Push trigger button 9 for 3s Start up Display After switching ON dito starts a self test routine to check the basic...

Page 4: ...selected in the Service Menu under Setting Evaluation This test routine helps to search for most sensitive test points at the DUT The dis charges are released with a higher repetition rate This routi...

Page 5: ...push once the trigger button 9 Cont trigger button must be pressed all time Rep the repetition rate of the discharges Functions Select By pushing a function key several times the operator can change b...

Page 6: ...ting Key Beep ON OFF Single beep Input confirmation if Key beep is ON Double beep Double beep always indicates warnings or failures e g No discharge Module No discharge relays available Battery voltag...

Page 7: ...e read in the dito and ditoControl manual Evaluation With the user can enter the menu Evaluation This menu can be used to check the DUT for most sensitive test points The preferred method to find thes...

Page 8: ...d libraries can be built up The complete test preparation is made All data are available on the computer Laboratory work Make dito ready for testing dito is connected to the computer and ditoControl i...

Page 9: ...the CD ROM drive of your computer 4 1 Installation If you have turned off Auto run double click the file named Setup exe in root directory of ditoControl CD This launches the installation that will gu...

Page 10: ...l Short form Introduction V 2 04 10 15 5 Start ditoControl Start MS Windows Start ditoControl double click on the ditoControl Icon The startup screen appears for approx 2s After that ditoControl shows...

Page 11: ...ito into remote via software The initial status of the dito is local It can be set into remote by clicking onto the state button in the status bar and selection of Remote It can also be set into remot...

Page 12: ...ator because the registration code is related to the actual dito device number 5 3 Mode ditoControl supports two different operation modes Easy and Expert mode For more information please refer to the...

Page 13: ...devices can be de scribed in Auxiliary Equipment and linked into the test report Testing Test Notes In Test Notes different test parameters can be predefined The test notes can be printed and used as...

Page 14: ...actory or to the responsible sales office WARNING Before operating the download check the battery condition of the dito simulator At first the installed firmware will be erased In case that afterwards...

Page 15: ...e the predefined test routines and standards can not be modified To activate the input protection please select the menu Working Input Protection Change Password Then enter the password The switching...

Reviews: