• Check the connector for transport damage before in-

stalling it. If the connector is damaged do not install it.

• The planner, the construction company or operating 

company are responsible for the positioning and ins-
tallation of the connector. Planning and installation er-
rors can adversely affect the reliable functionality of the 
connector and may represent a signi

fi

 cant potential for 

hazard.

•  After the connector is installed perform a tightness and 

function check.

4.2 Tools Required

The tools required for installation and assembly are not 
included with delivery.

4.3 Connect Thread Side

• The connector must be connected so it is free of 

mechanical stress.

• The connector can have a male thread (ISO, DIN, 

ANSI) and can be connected with various connecting 
elements of the 

em

technik system.

Cylindrical thread

Conical thread

Sealing is provided by a sealing collar for 

Cylindrical threads (G, M or UNF).

 A version with an O-ring is also possible.

Sealing is provided 

by the thread itself 

for Conical threads 

(NPT).

Sealing Collar

O-Ring

Thread

•  Each thread must always be connected with the same 

thread type.

• If a plastic connector is used in combination with a 

metallic male 

fi

 tting, additional sealing with Te

fl

 on® 

tape is recommended.

4.4 Torque Chart

Plastic

Thread

G 1/8“

G 1/4“

G 3/8“

G 1/2“

G 3/4“

PP

1.0–1.5

2.5

5.0–6.0

5.0

10.0

PVDF

1.0–2.0

5.0

5.0–7.0

10.0

15.0

All data in Nm

4.5 Fastening Options

For the connectors are no fastening options intended.

5 Commissioning

5.1 Precondition for Commissioning

• Protect against leaks: Take protective measures 

against exceeding the maximum permitted pressure 
due to possible pressure surges.

•  Check the tightness and function of the connector.
•  In new systems and after repairs, 

fl

 ush the line system 

to remove foreign materials.

6 Maintenance

•  When used as designated, the connector is practically 

wear-free and generally requires no maintenance.

•  The operating company must perform regular visual in-

spections of the connector according to the operating 
conditions to prevent leaks and damage.

7 Disposal

• When disposing of the connector and packaging, 

comply with the relevant disposal requirements and 
environmental protection regulations.

•  When disposing of connector, pay careful attention to 

any residues of toxic or corrosive media.

8 Return Delivery

Do not return before consulting with 

em

technik.

1. Please consult with 

em

technik.

2. Empty the connector properly.
3. Rinse and clean the connector thoroughly, especially 

if the media is being conveyed are harmful, explosive, 
hot, or hazardous in some other way.

4. For connectors that have been operated with aggres-

sive, corrosive, combustible, toxic or water polluting 
media, a completely 

fi

 lled in clearance certi

fi

 cate must 

always be included.

9 Troubleshooting / Fault 
 Recti

fi

 cation

Error

Possible Cause

Error 
Recti

fi

 cation

Connection 
between thread side 
and system leaking

Sealing surface is 
damaged

Use sealant, see 4.3