7
Desalination capacity without pump
up to 10 l/min*
Desalination capacity with pump
up to 20 l/min*
Tmax
45 °C
pH range
3-10
Pump connection
230 V AC, 16 A
Filter membrane service life
approx. 100,000 l**
* The throughput depends on the salt content of the raw water. The higher the salt content,
the lower the throughput.
** The service life of the filter membrane depends on the contamination level of the raw
water. Contaminants shorten the service life of the filter membrane.
5. Operation
5.1. Installing/replacing the filter membrane
1.
Disconnect the pump from the power supply
2.
Disconnect the device from the water supply and the
system to be filled
3.
Release the pressure
4. Open the single lever fitting (10) (lever pointing
forwards)
5. Open the aeration tap (3)
6. Open the cover (5) on the filter casing
7. Remove the spacer ring (14)
8. Remove the prefilter (16)
9. Remove the filter membrane (17) (tilt PUROTAP®
expert if required)
10. Unpack the new filter membrane. Please note: Open
the plastic bag close to the weld seam. The plastic
bag is reused for storing the membrane!
11.
Lubricate the connector (15) with silicone grease
12.
Insert the new filter membrane (17) with connector
(15) pointing down
13.
Insert a new fine filter (16)
10
5
14
16
17
3
15