elysator PUROTAP expert Installation And Operation Maintenance Download Page 5

5

2. Function

The PUROTAP® expert works on the basis of reverse osmosis. The flow pattern 

of the water inside the intricately designed tank is controlled in a way that 

enables the system to achieve incomparably high filtration velocities. With its 

integrated high pressure pump, the PUROTAP® expert achieves a throughput 

of 20 litres per minute or 1200 litres per hour.

The PUROTAP® expert pushes raw water at pressures of up to 18 bar through 

a filter membrane with a gauge width of less than one nanometre – this 

equates to one millionth of a millimetre. This holds back all dissolved solids 

and only pure water molecules pass through the membrane. The hyper 

filtered water is particularly suitable for technical applications since dissolved 

minerals, heavy metals and pesticides, as well as bacteria and organic matter, 

are removed from the water. The pH value is only slightly affected.

3. Standard delivery

•  PUROTAP® expert device

•  Label "demineralised"

•  Spacer ring, grey

•  Operating instructions

Summary of Contents for PUROTAP expert

Page 1: ...www elysator com Installation Function Operation Maintenance Operating instructions PUROTAP expert...

Page 2: ......

Page 3: ...iption 6 4 2 Dimensions 6 4 3 Performance data 6 5 Operation 5 1 Installing replacing the filter membrane 7 5 2 Connection 8 5 3 Commissioning 8 5 4 Combined meter 9 5 5 Troubleshooting 11 6 Maintenan...

Page 4: ...4 1 Safety instructions Not drinking water Maximum 45 C Maximum pressure 9 bar not constantly Flow rate max 10 l min without pump Flow rate max 20 l min with pump 45 9 bar 10 l min 20 l min...

Page 5: ...raw water at pressures of up to 18 bar through a filter membrane with a gauge width of less than one nanometre this equates to one millionth of a millimetre This holds back all dissolved solids and o...

Page 6: ...Combined meter 10 Single lever fitting assembly 11 Waste water outlet male thread 12 Pure water outlet male thread fully desalinated 13 Pressure gauge for pure water outlet 4 2 Dimensions Dimensions P...

Page 7: ...lter membrane 1 Disconnect the pump from the power supply 2 Disconnect the device from the water supply and the system to be filled 3 Release the pressure 4 Open the single lever fitting 10 lever poin...

Page 8: ...30 l min Where EN 1717 is applicable Germany a pipe separator must also be installed upstream of the filling station Observe the water utilities regulations PUROTAP expert may only be pressurised for...

Page 9: ...c quality monitoring Battery indication Limit Current conductivity value Set limit Select between S TDS Set key Each time the set key is pressed the limit is increased by 10 S cm or 6 TDS Hold the key...

Page 10: ...as well as the total water throughput are continuously displayed Press the key for approx 3 seconds to switch off the device If the combined meter is switched on and measures no throughput for about...

Page 11: ...y tap at the bottom prefilter spacer ring cover Has the cover been fitted correctly polished surface on the outside Is there carbon dioxide in the water This is not filtered out and increases conducti...

Page 12: ...d packaging it damp in the plastic bag it was delivered in The plastic bag should be sealed for example using a cable tie so that it is airtight and should be stored in a cool dark place The membrane...

Page 13: ...All rights and technical modifications reserved The current version can be found at www elysator com EN0421 13 8 Consumables Item no Designation 101 221 PUROTAP E90 membrane...

Reviews: