elysator PUROTAP compenso 12 Operating Instructions Manual Download Page 10

10

corresponds to approx. 20 µS/cm or 1 °dH corresponds to approx. 35 µS/cm. 

 

Sequence of units: µS/cm -- °C | µS/cm -- °F | TDS -- °C | TDS -- °F

ON/OFF key (MANU/AUTO)

Press the   key once to switch on the combined meter. The water quality is 

measured for 10 seconds and compared to the set limit. During measuring, 

the background is lit in blue and the conductivity value is displayed. If the 

measured value is below the set limit, everything is OK. If the measured value 

exceeds the limit, the display flashes red, an alarm signal sounds and the 

floating contact switches over (only when using the optional power supply 

unit). The present throughput and the water temperature, as well as the total 

amount of water throughput, are continuously displayed. Press the key for 

approx. 3 seconds to switch off the device. If the combined meter is switched 

on and measures no throughput for about one hour, it automatically switches 

off. During operation with the optional power supply unit, the combined 

meter does not automatically switch off and cannot be switched off manually. 

If the combined meter has switched off automatically, it will automatically 

restart once throughput (> 2 l/min) resumes. If the combined meter is 

switched off using the ON/OFF key, it will not restart automatically. 

Auto mode

Press the   key

 

twice in quick succession to start automatic monitoring by 

the combined meter. The 

 symbol appears to indicate that monitoring has 

been enabled. In auto mode, the meter only takes measurements when 

water is actually passing over it. If the throughput is interrupted, the meter 

continues to show the last captured value. When a throughput is present, the 

meter takes a new reading of the conductivity value after every 10 litres and 

displays it. If the limit is exceeded in two successive measurements, the 

display continuously flashes red and an acoustic alarm sounds. In addition, 

the floating contact is switched over. If the   key is pressed for a third time, 

the meter exits auto mode. Auto mode is recommended for operation with 

an automatic topping up device.

Summary of Contents for PUROTAP compenso 12

Page 1: ...www elysator com Installation Function Operation Service Operating instructions PUROTAP compenso...

Page 2: ......

Page 3: ...cification 4 1 Device description 6 4 2 Dimensions 6 4 3 Performance data 7 5 Installation 5 1 Connection 7 5 2 Combined meter 9 6 Maintenance 6 1 Replacing the resin 11 6 2 Changing the combined mete...

Page 4: ...4 1 Safety instructions Not drinking water Maximum 60 C Maximum 4 bar pressure 4 bar...

Page 5: ...changer to provide deionised fully desalinated water softened water for systems of all sizes This method does not emit any chemical additives into the water The appliance operates without an external...

Page 6: ...ced hose 8 Wall mounting bracket 4 Resin canister 9 Air vent 5 Drain valve 4 2 Dimensions PUROTAP compenso 2 compenso 12 compenso 25 compenso 50 Installed length 45 cm 80 cm 80 cm 80 cm Height 46 cm 7...

Page 7: ...ll hose 1 Flush the cartridge Open the valves Connect a hose from the appliance to the drinking water supply Route a further hose from the connection on the combined meter side to a bucket Flush the c...

Page 8: ...ter utilities regulations must stringently be observed e g system separation to DIN EN 1717 Close all taps and valves on the heating and drinking water networks after use Safety instructions If perman...

Page 9: ...gramming the limit ensures that a warning is issued when the ion exchange resin is spent If the set limit is exceeded the backlight flashes red and an acoustic alarm sounds In addition the floating co...

Page 10: ...h the optional power supply unit the combined meter does not automatically switch off and cannot be switched off manually If the combined meter has switched off automatically it will automatically res...

Page 11: ...0 We recommend resetting the JOB to 0 after every resin change to enable estimating and comparing the residual capacity of the ion exchange resin The TOTAL litres cannot be reset to 0 6 Maintenance 6...

Page 12: ...he newly added resin at the same time This makes centring the brass head much easier Connect the reinforced hoses reset the combined meter to 0 see chapter 5 2 6 2 Changing the batteries on the combin...

Page 13: ...100811 Immersion pipe 100556 100967 100968 100739 Canister 100203 100201 100202 100204 8 Consumables PUROTAP compenso 2 compenso 12 compenso 25 compenso 50 HF 1 7 l highpower 100920 HF 12 5 l highpowe...

Page 14: ...ical modifications reserved The current version can be found at www elysator com EN0721 14 9 Accessories PUROTAP compenso 2 compenso 12 compenso 25 compenso 50 LFM 20 mains unit plus connector 102280...

Page 15: ...Service booklet Installer Date of installation Project Device no Sludge removal interval Maintenance interval Date Job Meter mA Company signature...

Reviews: