Personal code entry sequence: 

 + <code> + 

.

5.5.2.

 

Display feedback

The device returns the status information associated with the entry control phase:

Access to the 

mode for

Entry control

     

Entering code

     

Waiting for 

confirmation

Code

Delete

Confirm

     

Code

Delete

Confirm

     

Code

Delete

Confirm

Feedback on actuation, after entering the code:

Done

     

Not completed

Done

     

Wrong code

5.6.  Wait screens

The following screen will show when starting up the device. Wait for completion of the relevant phase.

Starting

Loading...

Summary of Contents for 41018

Page 1: ...Manuale installatore Installer guide 41018 Display 3 5 in 3 5 in Display ...

Page 2: ...pliances marked with the crossed out wheelie bin symbol must be collected in accordance with the instructions issued by the local authorities responsible for waste disposal ENGLISH 1 BRIEF DESCRIPTION OF DEVICE The display module provides the function of calling via the contacts list of the panel on which it is installed If the panel has a keypad art 41019 calls to the indoor units can also be mad...

Page 3: ...20 x 480 pixels 65K colours 500 lux The device must always be accompanied by an audio video or audio module Power supply 5V DC from audio video or audio module via harness Maximum current draw 220 mA When connect ing the modules observe the limit of the maximum current that can be supplied by the specific Audio Video module being used if it is necessary to provide an independent power supply to th...

Page 4: ...s like this Without a keypad With a keypad installed Press After programming the contacts list the standby view looks like this Without a keypad With a switchboard With a switchboard and keypad Contacts Press Porter Contacts Extension Contacts Porter 3 2 Setting contacts list filters SaveProg lets you enable a set of filters for targeted access to the subsets of the contacts list The available fil...

Page 5: ...s 3 2 3 Stair filter The Stair filter lets you access the subset of users paired with a specific stair or all users It can be combined with the two previous filters In particular with the buildings filter you obtain Extension Contacts Porter Buildings Stairs Stair A Stair B Stair E Stair D Stair C Users Stair A With the buildings and names filter Extension Contacts Porter Buildings Stairs Stair A ...

Page 6: ...ally from the names in the contacts list paired with the same extension number A second name Extension Contacts Porter Users Back OK 3 4 Updating The device can be updated via its USB port Follow the WinBoot user instructions To update the module you need to disconnect the bus wiring harness disconnect any auxiliary power supply connect the USB port to the PC and start the update within 10 s of th...

Page 7: ...Label Settings Level 0 Level 1 Level 2 Display Language Italian English French German Spanish Greek and Portuguese Default Italian Menu Navigation Navigable Direct Default Navigable Font Normal Large Default Normal LCD Brightness 1 5 Default 5 Colours B W BLUE GREEN Default B W Standby ON OFF Default ON The items are accompanied by the current value of the set parameter 4 1 1 Language This lets yo...

Page 8: ...ing parameters of the display Brightness 0 5 Brightness level Colours B W BLUE GREEN Lets you select one of the predefined colour schemes for viewing the menu according to readability Extension Delete Confirm Extension Delete Confirm Extension Delete Confirm B W BLUE GREEN Standby ON OFF Lets you disable display standby mode i e not decreasing the brightness level of the LCD when it is not being u...

Page 9: ...lues Talk 10 values Info AV FW Ver xxxxx LCD FW Ver xxxxx KP FW Ver xxxx System Reset Settings OK C Confirm Delete Reset Panel OK C Confirm Delete Reboot Panel OK C Confirm Delete Reboot Installation OK C Confirm Delete The Display section is described in the previous chapter 4 1 Administrator menu 4 3 Panel This section lets you set the basic parameters of the audio video module of the panel Refe...

Page 10: ... Info This section gives the release information for the devices installed on the panel 4 5 System This section lets you restore the factory settings of the various devices or restart the panel Reset Settings Yes No Restores the factory default settings of the display module after confirmation Reset Panel Yes No Restores the factory default settings of the panel after confirmation Reboot Panel Yes...

Page 11: ...through the sequence of pre filters and select the contacts list entry you want to call Back Pressing OK cancels the current call 5 1 1 Searching for a name in the contacts list You can search for a specific name in the contacts list also by using the multi tap function of the keypad From the list of names in the contacts list press the letters forming the name on the keypad Each button must be pr...

Page 12: ...is a keypad you can directly enter the extension number you want to call Enter the extension number by following the indications on the display OK sends the call C clears the entry Extension Contacts Porter Extension Delete Confirm If the extension keyed in does not match a valid number a warning is issued Invalid 5 4 Call information The device returns the status information associated with the c...

Page 13: ...ation of the entry control mode This mode lets you activate a previously configured command e g lock relay etc For its operation please refer to the instructions of the keypad module summarized here 5 5 1 Operation The keypad has 2 function keys referred to here as and Press the button and the display to go into Code Entry mode Each time a digit button is pressed the display will show the digit fo...

Page 14: ...cess to the mode for Entry control Entering code Waiting for confirmation Code Delete Confirm Code Delete Confirm Code Delete Confirm Feedback on actuation after entering the code Done Not completed Done Wrong code 5 6 Wait screens The following screen will show when starting up the device Wait for completion of the relevant phase Starting Loading ...

Page 15: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com 49400688A0 00 1506 VIMAR Marostica Italy ...

Reviews: