28
7” Due Fili Plus porter switchboard
Competence Areas (CA)
A Related Zone, hereinafter CA, is an extension of the Indoor / Outdoor mode of the switchboard and automatic Indoor /
Outdoor mode.
CAs are configured exclusively using Project Mode of the SaveProg software. When they are configured, the
key
will have no effect.
Strictly speaking, the CA consists of a list of:
1. Indoor units only
2. Speech units only
3. Indoor and speech units
which are served by the switchboard. The CA definition must be identical for all the switchboards in the same installation.
The CAs are subsequently associated with the day/s of the week (or holidays), and for each of these to time bands with
subdivisions of 30 minutes.
In each of these three cases, the management procedure is as follows:
1. The indoor units that make a call to a generic switchboard are served by all the switchboards that have those units
in an active CA. Calls purposely originated from indoor units are served in any case.
2. Calls originating from the indicated speech units and directed towards any switchboard, are managed by the
switchboards that have those speech units in an active CA.
3. Calls originating from one of the speech units in the list AND SIMULTANEOUSLY directed to one of the indoor units
in the list are served by all those switchboards that have both of them in an active CA.
Call Filter
When the call filter is enabled, the switchboard will no longer receive calls from indoor units. Two separate filters can be
configured. The Indoor Call Filter, if enabled, is applied when switchboard is in Indoor mode. Conversely, the Outdoor Call
Filter, if enabled, is applied when switchboard is in Outdoor mode. The two filters can be enabled and disabled indepen-
dently of each other, but only using SaveProg. When a filter is active, the icon
appears alongside the relative Indoor/
Outdoor mode icon.
Programmable keys
Keys
and
are programmable and by default respectively execute commands F1 and F2 for the speech unit in
conversation. In standby, the commands are sent to the last speech unit which was contacted or which called.
The keys can only be programmed using SaveProg. The programmable functions are: intercom, self-start, auxiliary function
activation, F1 function, F2 function, lock activation.
Dial a number and then press the
key to command the F1 output of the speech unit corresponding to the number
dialled. Similarly, dial a number and then press the
key to command the F2 output of the speech unit corresponding
to the number dialled. This function is executed independently of the function programmed using SaveProg.
Search contacts list
Press the key
to access the contacts list in List display mode.
For each element, the ID of the speech unit (possibly preceded by the √ symbol, if it is the main name associated with that