EVMU30 

EVMU40 

Charging interface 

SAE J1772 compliant charging plug 

Input rating 

208-240 Vac, single 

 

208-240 Vac, single 
phase, 30 A max., 60 Hz 

208-240 Vac, single 
phase, 40 A max., 60 Hz 

Wiring for 

hardwired models 

L1, L2, and Ground, hardwired with terminal block; bottom-fed 

Wall plug for cord 
connected models 

 

NEMA 6-50P 

NEMA 6-50P 

Output rating 

 

208-240 Vac, single 
phase, 30 A max., 60 Hz 

208-240 Vac, single 
phase, 40 A max., 60 Hz 

Standby power 

< 5 W 

Metering 

Embedded non-revenue grade meter with 1% accuracy   

Output rating 

 

208-240 Vac, single 
phase, 30 A max., 60 

Hz, 7.2 kW 

208-240 Vac, single 
phase, 40 A max., 60 
Hz, 9.6 kW 

Internal residual 
current detection 

20 mA CCID per UL 2231 

Upstream breaker 

 

 

2-pole 40 A breaker on 
dedicated circuit, 
non-GFCI type 

2-pole 50 A breaker on 
dedicated circuit, 
non-GFCI type 

Electrical protection  Over current, short circuit, over voltage under voltage, ground fault, surge 

protection, over temperature 

Status indicators 

AC present, charging, fault 

Buttons/Switches 

Charger on/off, stop charging 

Option: Network 
interface 

WLAN 

Operating temp. 

-22  °F  to +122  °F  (-30 °C  to +50 °C) 

Humidity 

95% related humidity, non-condensing   

Charging cable 
length 

18 ft (5.5 m) straight cable 

Ingress protection 

Type 3R 

Cooling 

Natural cooling 

Dimension 
(W x H x D)

 

12.6 x 10.3 x 4.5 in (320 x 260 x 115 mm), excluding charging cable, mounting 
plate and cable holder 

Net weight 

5 lbs (2 kg) excluding charging connector and cable 

Certificate 

UL, cUL 

Specifications

Installation-manual_CH-211
v1.0.4

CH-21130

CH-21140

Summary of Contents for GridCharge

Page 1: ...orkplace W Public MuD e Installation Manual Warranty ...

Page 2: ...arranty 8 This document provides instructions for the eluminocity GridCharge and should not be used for any other product This product should be installed only by a licensed contractor and or a licensed electrician and in accordance with all applicable state local and national electrical codes and standards Table of Contents Installation manual_CH 211 v1 0 4 ...

Page 3: ... 0 4 Inside this box you will find 1 GridCharge EV Charger 2 Mounting Bracket 3 Torx T30 bolts x2 4 1 4 inch expansion bolts x3 5 No 8 wood screws x3 If any parts are damaged or missing please contact us at salesUS eluminocity com ...

Page 4: ...fying a range of values or a nominal value of tightening torque to be applied to the clamping screws of the terminal connectors Only for hardwired unit CAUTION To reduce the risk of fire connect only to a circuit provided with below amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code ANSI NFPA 70 Model Current rating CH 21140 50 A CH 21130 40 A Onl...

Page 5: ... before working inside the equipment or removing any component Do not remove Grounding Instructions The eluminocity GridCharge must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the product Recommended Tools The following tools are recommended for elum...

Page 6: ... wood studs use 8 wood screws of 2 or above screw length and torque to 26 lb in 3 N m 3 Align the screw holes of the mounting bracket with the eluminosity GridCharge Install and secure the eluminosity GridCharge on the mounting bracket with the two 2 Torx T30 screws supplied Torque to 13 lb in 1 5 N m 4 Secure the mounting bracket and the optional cable hanger bracket to the wall with appropriate ...

Page 7: ...wire type CH 21140 No 6 AWG 90 ºC CH 21130 No 8 AWG 75 ºC or 90 ºC Note Choose appropriate conduit in accordance with all applicable state local and national electrical codes and standards 9 Replace the compartment cover and torque to 8 7 lb in 1 0 N m 10 Replace the front cover by aligning the hinge on the top Secure the front cover by the bottom screw torque to 10 4 lb in 1 2 N m 11 Place the ch...

Page 8: ... mA CCID per UL 2231 Upstream breaker 2 pole 40 A breaker on dedicated circuit non GFCI type 2 pole 50 A breaker on dedicated circuit non GFCI type Electrical protection Over current short circuit over voltage under voltage ground fault surge protection over temperature Status indicators AC present charging fault Buttons Switches Charger on off stop charging Option Network interface WLAN Operating...

Page 9: ...hout a prior authorized RMA Product must be returned with a copy of the original dealer invoice or written proof of installation In the event Customer transfers ownership of Product to a third party the warranty will only transfer to the third party if the Product remains installed at the original site Product must also include a legible data label showing the serial number Product must be returne...

Page 10: ...or the supply of energy from the Product Missing items ex screws brackets Installation by a non licensed contractor Limitation of Liability TO THE EXTENT PERMITTED BY APPLICABLE LAW OTHER THAN THE EXPRESS WARRANTY SET FORTH IN THIS WARRANTY ELUMINOCITY MAKES NO ADDITIONAL WARRANTIES EXPRESS OR IMPLIED AND DISCLAIMS ALL IMPLIED WARRANTIES WHETHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWIS...