Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 5-pin XLR connector for data input/output,  
see image below.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL185 – 2m
CABL187 – 5m
CABL188 – 10m

Summary of Contents for ELUM094

Page 1: ...Order codes ELUM094 100W 3200K WW Version ELUM095 100W 6000K CW Version ELUM096 150W 3200K WW Version ELUM097 150W 6000K CW Version PF LED Profile User Manual ...

Page 2: ...d off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC...

Page 3: ...rate Beam framing shutters Gobo slot Gobo size 70mm DMX channels 1 or 2 selectable 0 100 dimming 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 3 push button menu with LCD display PowerCON input output 5 Pin XLR input output Temperature controlled fan cooling Handle on rear panel Filter frame included Supplied with gobo holder PF LED Profile Spec...

Page 4: ...ss the 2 channel DMX mode press the MENU button on the rear of the unit to show DMX 2CH on the LCD display The fixture is now in 2 Channel mode Now use the UP and DOWN buttons to set the desired DMX address for the 2 Channel mode To exit out of any of the above options press the MENU button Technical specifications Operating instructions 01 Earth point 02 LCD display 03 On Off switch 04 Function b...

Page 5: ...uar LED Inverse Square dimming curve Led S Curve LED S Curve dimming curve Halgen Linear Halogen Linear dimming curve Halgen Square Halogen Square dimming curve Halgen InvSquar Halogen Inverse Square dimming curve Halgen S Curve Halogen S Curve dimming curve To exit out of any of the above options press the MENU button Channel Value Function 1 000 255 Master dimmer 0 100 2 000 014 Dimming Curves s...

Page 6: ...X is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing...

Page 7: ...pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advis...

Page 8: ...sible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally ...

Reviews: