background image

Order code: ELUM085

Matrix Tri Pixel Panel 25 MKII 

User Manual

Summary of Contents for ELUM085

Page 1: ...Order code ELUM085 Matrix Tri Pixel Panel 25 MKII User Manual ...

Page 2: ...he equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz Make sure that the power cable is never crimped or damaged Check...

Page 3: ...lly addressable LEDs DMX channels 3 5 6 25CW 25WW 26 75 76 78 or 100 selectable Sound active auto and master slave modes plus built in programs 0 100 dimming and variable strobe Supplied with individual flying yoke 4 push button menu with LCD display PowerCON input output RJ45 Ethernet input output 3 Pin XLR input output 5 Pin XLR input output Temperature controlled cooling fans Quarter turn quick...

Page 4: ...r turn quick lock rigging system 15 Safety eyes 16 Microphone In the box 1 x fixture 1 x flying yoke bracket 1 x 13A powerCON mains cable 1 x user manual DMX OCCUPATION 1 GROUND 2 SIGNAL 3 SIGNAL DMX OCCUPATION 1 GROUND 2 SIGNAL 3 SIGNAL 4 NC 5 NC ENTER MODE UP DOWN SAFETY EYE LOCK IN OPEN LOCK IN OPEN SAFETY EYE www prolight co uk TRI PIXEL PANEL 25 MKII MIC SAFETY EYE SAFETY EYE DMX IN DMX IN PO...

Page 5: ...D 9 0 100 10 000 255 LED 10 0 100 11 000 255 LED 11 0 100 12 000 255 LED 12 0 100 13 000 255 LED 13 0 100 14 000 255 LED 14 0 100 15 000 255 LED 15 0 100 16 000 255 LED 16 0 100 17 000 255 LED 17 0 100 18 000 255 LED 18 0 100 19 000 255 LED 19 0 100 20 000 255 LED 20 0 100 21 000 255 LED 21 0 100 22 000 255 LED 22 0 100 23 000 255 LED 23 0 100 24 000 255 LED 24 0 100 25 000 255 LED 25 0 100 25C co...

Page 6: ... 0 100 26 000 025 Red 026 050 Green 051 075 Blue 076 100 Yellow 101 125 Pink 126 150 Purple 151 175 Cool white 176 200 Warm white 201 225 Colour fade slow fast 226 255 Colour change slow fast 26 channel mode Channel Value Function 1 000 255 LED 1 0 100 2 000 255 LED 2 0 100 3 000 255 LED 3 0 100 4 000 255 LED 4 0 100 5 000 255 LED 5 0 100 6 000 255 LED 6 0 100 7 000 255 LED 7 0 100 8 000 255 LED 8...

Page 7: ...100 G9 0 100 B9 0 100 R10 0 100 G10 0 100 B10 0 100 R11 0 100 G11 0 100 B11 0 100 R12 0 100 G12 0 100 B12 0 100 CH37 CH38 CH39 CH40 CH41 CH42 CH43 CH44 CH45 CH46 CH47 CH48 R13 0 100 G13 0 100 B13 0 100 R14 0 100 G14 0 100 B14 0 100 R15 0 100 G15 0 100 B15 0 100 R16 0 100 G16 0 100 B16 0 100 CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 CH59 CH60 R17 0 100 G17 0 100 B17 0 100 R18 0 100 G18 0 10...

Page 8: ... B9 0 100 R10 0 100 G10 0 100 B10 0 100 R11 0 100 G11 0 100 B11 0 100 R12 0 100 G12 0 100 B12 0 100 CH37 CH38 CH39 CH40 CH41 CH42 CH43 CH44 CH45 CH46 CH47 CH48 R13 0 100 G13 0 100 B13 0 100 R14 0 100 G14 0 100 B14 0 100 R15 0 100 G15 0 100 B15 0 100 R16 0 100 G16 0 100 B16 0 100 CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 CH59 CH60 R17 0 100 G17 0 100 B17 0 100 R18 0 100 G18 0 100 B18 0 100 ...

Page 9: ... 031 G 032 039 B 040 047 RG 048 055 GB 056 063 RB 064 071 RGB 072 079 Colour 1 080 087 Colour 2 088 095 Colour 3 096 103 Colour 4 104 111 Colour 5 112 119 Colour 6 120 127 Colour 7 128 135 Colour 8 136 143 Dream Speed slow fast 144 151 Meteor 152 159 Fade 160 167 Change 168 175 Flow 1 176 183 Flow 2 184 191 Flow 3 192 199 Flow 4 200 207 Flow 5 208 215 Flow 6 216 223 Flow 7 224 231 Flow 8 232 239 F...

Page 10: ...00 B11 0 100 Dimmer 11 0 100 R12 0 100 G12 0 100 B12 0 100 Dimmer 12 0 100 CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 CH59 CH60 R13 0 100 G13 0 100 B13 0 100 Dimmer 13 0 100 R14 0 100 G14 0 100 B14 0 100 Dimmer 14 0 100 R15 0 100 G15 0 100 B15 0 100 Dimmer 15 0 100 CH61 CH62 CH63 CH64 CH65 CH66 CH67 CH68 CH69 CH70 CH71 CH72 R16 0 100 G16 0 100 B16 0 100 Dimmer 16 0 100 R17 0 100 G17 0 100 B...

Page 11: ...MODE button to show SLAVE MODE on all of the slave units Now the slave units will follow in conjunction with the master unit Press the ENTER button to confirm your setting To exit out of any of the above options press the MODE button Built in programs To access the built in program press the MODE button to show 01 STATIC on the LCD display Now press the ENTER button and use the UP and DOWN buttons...

Page 12: ... note An IP address in ArtNet topology generally starts with 2 x x x or 10 x x x with 255 0 0 0 for netmask To exit out of any of the above options press the MODE button Built in programs Value Function Static colour CL BLAC RGB Flash 00 99 Blackout Red Yellow Green Cyan Blue Purple White Flash speed adjustable Dream Speed 00 99 Flash 00 99 7 colour dream Speed flash ajustable Meteor Speed 00 99 F...

Page 13: ...r the number of units in one chain should be limited to 10 units to avoid unwanted signal delays In bigger installations you should use the STAR topology using ethernet switches or a combination of both Internally the selected DMX universe is treated as a normal DMX signal so further setup of the DMX address and channel mode should be done as usual Thanks to the internal Art Net node all 512 chann...

Page 14: ...ty cable that can hold 12 times the weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails The device should be well fixed a free swinging mounting is dangerous and should not be used Don t cover any ventilation openings as this may result in overheating Riggin...

Page 15: ... to the unit Place the flying bracket on top of the unit making sure that both carry handles are folded flat Line up the bracket with the steel locating pins Now using a size 8 allen key turn the coffin lock and turn anti clockwise until you hear it lock into position Make sure that you hear a click and cannot turn the lock any more Fix 2 suitable safety cable s to the safety eyes to make sure the...

Page 16: ... at the top NOTE Please be sure that each unit is fixed together properly using the coffin locks on the left side and bottom side of the unit following the same method for the flying bracket When the units are lined up against each other use a size 8 allen key to turn the coffin lock turn the coffin lock anti clockwise until you hear it lock into position Make sure that you hear a click and cannot...

Page 17: ...25 will show Unit name Tri Pixel Panel 25 Manufacturer Elumen8 Category LED Dimmer Firmware XXXX version of the software of the unit DMX address XXX current DMX start address of the unit DMX footprint XX current number of DMX channels used by the unit Personality XX current working DMX mode personality of the unit The DMX controller can send certain commands to each to each RDM unit which allows r...

Page 18: ...linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX ...

Page 19: ...CABL89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is alw...

Page 20: ...vent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environm...

Reviews: