background image

     

 

1 A 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ELUM053

Page 1: ...ELUM053 User Manual Please read the user manual before use ...

Page 2: ...1 A ...

Page 3: ...2 A Table of Contents 1 Safety Information 3 2 Rear Panel 5 3 Preparation for Use 5 4 Main Functions 6 5 Remote Control 10 6 Technical Specification 12 ...

Page 4: ...wer that complies with local building and electrical codes and has both overload and ground fault protection Do not expose the fixture to rain or moisture To guard against UV radiation burns and fire Never operate the fixture with the front glass open missing or damaged Do not stare directly into the light Never look at an exposed LED while it is lit Never attempt to bypass the fuse Always replace...

Page 5: ...n approved means of secondary attachment such as a safety cable Block access below the work area whenever installing or removing the fixture To guard against epileptic seizure Do not operate the fixture near stairways Provide advance notice that strobe lighting is in use Avoid extended periods of continuous flashing particularly at frequencies of 10 to 20 flashes per second For AC 220 240V power s...

Page 6: ...resent Master On Master Slave On Slave Sound Flash Sound activation 5 Menu UP DOWN Enter button 6 DMX input output 7 Microphone Receive music signal for sound active mode 8 CA 8 Connector Connect with easy controller CA 8 3 Preparation for Use INSTALLATION The Plasma 1K White may be installed in any orientation The mounting bracket provides five 12 mm holes for direct fastening or attachment of ri...

Page 7: ...d the MENU button for 1 second The main menu as follows DMX 512 address setting Select ADDR option and the display will blink press the ENTER button to confirm your selection You can check the current DMX address on the display The DMX address can be changed by pressing the UP DOWN buttons and then press the ENTER button to confirm your selection Wait for 30 seconds to return to the main menu or h...

Page 8: ...ns Press the ENTER button to confirm your selection Wait for 30 seconds to return to the main menu or hold the MENU button for 1 second Show Dimmer Select the option and press the ENTER button to confirm your selection Select the dimmer value from by pressing the UP DOWN buttons Press the ENTER button to confirm your selection Wait for 30 seconds to return to the main menu or hold the MENU button ...

Page 9: ...main menu or hold the MENU button for 1 second Sound mode will only be available once the fixture is set as a master unit Sound sense Select the option and press the ENTER button to confirm your selection Select the sensitivity from 000 100 by pressing the UP DOWN button Press the ENTER button to confirm your selection Wait for 30 seconds to return to the main menu or hold the MENU button for 1 se...

Page 10: ...tic test Once the self test has finished it will return to the test menu Wait for 30 seconds to return to the main menu or hold the MENU button for 1 second Temperature Select the TEMP option and press the ENTER buttons the display will show the temperature of unit Wait for 30 seconds to return to the main menu or hold the MENU button for 1 second Defaults Select the DEF option and press the ENTER...

Page 11: ...er e g b 10 v 10 and check it by using the UP DOWN buttons Wait for 30 seconds to return to the main menu or hold the MENU button for 1 second 5 Remote Control 1 Channel Mode Channel Value Function 1 0 5 Blackout 6 250 Flash rate slow to fast 251 255 Continuous Blinder effect 2 Channel Mode Channel Value Function 1 0 5 Blackout 6 255 Flash rate slow to fast 2 Flash intensity 0 5 Blackout 6 255 Min...

Page 12: ...5 0 5 25 Hz 50 Hz AC or 0 6 30 Hz 60 Hz AC 4 Channel Mode Channel Value Function 1 Flash intensity 0 5 Blackout 6 255 Minimum to maximum 2 Flash duration 0 255 0 650 ms 50 Hz AC or 0 530 ms 60 Hz AC 3 Flash rate 0 5 No flash single flash with ch 1 6 255 0 5 25 Hz 50 Hz AC or 0 6 30 Hz 60 Hz AC 4 Special effects 0 5 No effect 6 50 Ramp up 51 100 Ramp down 101 150 Ramp up down ...

Page 13: ... Light flashes randomly with variable rate and intensity Multiple units flash independently of each other Single Flash To trigger single flashes start with the intensity and flash rate at 0 and then set the intensity on channel 1 When the value of channel 1 is changed the light will flash once with the programmed intensity duration and effect 6 Technical Specifications AC power 100 240 V 50 60 Hz ...

Page 14: ...13 A ...

Page 15: ...14 A ...

Page 16: ...15 A ...

Page 17: ...16 A Innovation Quality Performance ...

Reviews: