DMX-512: 

• DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is 

sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located 

on all DMX fixtures (most controllers only have a data “out” terminal).

DMX Linking: 

• DMX is a language allowing all makes and models of different manufactures to be linked together and operate 

from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data 

transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which 

fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned 

to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the 

middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to 

address 1 to that unit, no matter where it is located in the DMX chain.

DATA Cable (DMX cable) requirements (for DMX operation):

• The 100W LED Alu CW/WW can be controlled via DMX-512 protocol. The DMX address is set on the back of 

the unit. Your unit and your DMX controller require a standard 3-pin or 5-pin XLR connector for data input/output

(figure 1). 

 

Figure 1

Also remember that DMX cable must be daisy chained and cannot be split.

Summary of Contents for ELUM043

Page 1: ...100W LED Alu CW WW User Manual Code ELUM043 ...

Page 2: ...1 ...

Page 3: ...2 ...

Page 4: ...W LED Dimming master slave and DMX modes 400Hz refresh rate 5 pin XLR in out sockets 4 push button menu with LCD display Powercon in socket Beam angle 60 degrees Power supply 100 240V 50 60HZ Power consumption 130W Weight 4 9Kgs Operating modes 1 Dimming 0 100 2 DMX 3 Master slave 4 Channel select 5 Dimming curves Overview 3 DMX OUT DMX IN FUSE F2A 250V MENU ENTER UP DOWN LCD DISPLAY POWER IN ...

Page 5: ...imming curves from 01 08 1 4 are for halogen response type 01 Linear 02 Square 03 Inverse square 04 S curve 5 8 are for LED response type 05 Linear 06 Square 07 Inverse square 08 S curve When you are happy with your setting press the ENTER button to confirm it LINEAR the increase in light intensity appear to be linear as DMX value is increased SQUARE light intensity control is finer at low levels ...

Page 6: ...0 Function Cool White Warm White Master Dimmer 0 100 Strobe slow to fast 17 Colour Temperature Macro Selector Function Cool White Warm White Master Dimmer 0 100 Strobe slow to fast 17 Colour Temperature Macro Selector Dimmer curve and response select on fixture Dimmer curve Linear response halogen Dimmer curve Square response halogen Dimmer curve Inverse Square response halogen Dimmer curve S resp...

Page 7: ...ission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send ...

Page 8: ...ratic behaviour Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details ...