background image

Order codes: ELUM017

Kudos 60 Beam 

User Manual

Summary of Contents for ELUM017

Page 1: ...Order codes ELUM017 Kudos 60 Beam User Manual ...

Page 2: ... short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz...

Page 3: ...inuous pan and tilt 8 bit 16 bit pan and tilt RDM Remote Device Management Fast and agile movement for enhanced pan tilt effects Quick release omega clamp included 6 push button menu with 1 8 LCD display with 180 reverse function PowerCON input output 3 Pin XLR input output 5 Pin XLR input output Fan cooled with adjustable speed for low noise operation Kudos 60 Beam Specifications Kudos 60 Beam Po...

Page 4: ... 5 Pin DMX output 08 PowerCON input 09 PowerCON output 10 Fuse T2A 250V In the box 1 x fixture 1 x 10 lens 1 x 45 frost lens 1 x omega clamp 1 x power cable 1 x user manual POWER INPUT 100 240V 50 60Hz FUSE T2A 250V 3 PIN DMX INPUT 5 PIN DMX INPUT 3 PIN DMX OUTPUT 5 PIN DMX OUTPUT POWER OUTPUT MENU UP Kudos 60 Beam LEFT ENTER RIGHT DOWN DISPLAY BACKUP 04 07 01 02 03 08 06 05 10 09 ...

Page 5: ...es 10 and 45 See below for installation instructions 1 Place the fixture on a flat surface and unscrew the plastic cover 2 Remove plastic cover from the head 4 Place the plastic cover back on the head 5 Tighten the screws until the plastic cover is secure 3 Carefully place the required frost lens over the centre of the LED reflector ...

Page 6: ...he option value required Once the option value has been selected press the ENTER button once more to confirm the setting To exit out of any of the above options press the MENU button The LCD control panel can be used via the internal battery To access this press and hold the DISPLAY BACKUP button for 5 seconds until the fixtures home screen is displayed The LCD display will automatically shut off ...

Page 7: ...ting Temp C F Celsius Fahrenheit Temperature display C F Disp Ser Chan Value ALL Auto Pro PAN PAN Fine TILT TILT Fine Move Sp Strobe Dim mer Red1 Green1 Blue1 White1 Chase Chase Sp Dim Modes PANConRot TILTConRot Color Macro DimmerFine Chase Fade Channel Value Display 000 255 Slave Set Slave 1 Follows master unit Slave 2 Follows master PAN TILT invert Slave 3 Follows master PAN TILT invert on occas...

Page 8: ...power the fixture on Set the DMX value of Channel 1 to 007 on the controller Then set the DMX value of Channel 2 to 007 or 008 on the controller 007 allows the address to be set from 001 255 008 allows the address to be set from 256 511 Now use Channel 3 on the controller to set the required DMX address After setting Channel 3 to the required DMX address wait for approximately 20 seconds for the f...

Page 9: ...5 5 7 000 255 Red dimmer 0 100 6 6 8 000 255 Green dimmer 0 100 7 7 9 000 255 Blue dimmer 0 100 8 8 10 000 255 White dimmer 0 100 9 9 11 000 No function 001 004 Colour Macro 1 005 008 Colour Macro 2 009 012 Colour Macro 3 013 016 Colour Macro 4 017 020 Colour Macro 5 021 024 Colour Macro 6 025 028 Colour Macro 7 029 032 Colour Macro 8 033 036 Colour Macro 9 037 040 Colour Macro 10 041 044 Colour M...

Page 10: ...1 144 Colour Macro 36 145 148 Colour Macro 37 149 152 Colour Macro 38 153 156 Colour Macro 39 157 160 Colour Macro 40 161 164 Colour Macro 41 165 168 Colour Macro 42 169 172 Colour Macro 43 173 176 Colour Macro 44 177 180 Colour Macro 45 181 184 Colour Macro 46 185 188 Colour Macro 47 189 192 Colour Macro 48 193 196 Colour Macro 49 197 200 Colour Macro 50 201 204 Colour Macro 51 205 208 Colour Mac...

Page 11: ... 014 LEDs Off 015 030 Auto Program 1 031 046 Auto Program 2 047 062 Auto Program 3 063 078 Auto Program 4 079 094 Auto Program 5 095 110 Auto Program 6 111 126 Auto Program 7 127 142 Auto Program 8 143 158 Auto Program 9 159 174 Auto Program 10 175 190 Auto Program 11 191 206 Auto Program 12 207 222 Auto Program 13 223 238 Auto Program 14 239 255 Auto Program 15 14 13 16 000 255 Auto Program Speed...

Page 12: ...while dark 236 255 No function 18 16 20 000 079 No function 080 084 Motor reset 085 099 No function 100 119 Internal Program 1 120 139 Internal Program 2 140 159 Internal Program 3 160 179 Internal Program 4 180 199 Internal Program 5 200 219 Internal Program 6 220 239 Internal Program 7 240 255 No function DMX channel modes Operating instructions ...

Page 13: ...DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressi...

Page 14: ...pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advis...

Page 15: ...sible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally ...

Page 16: ...www prolight co uk Kudos 60 Beam User Manual 16 ...

Reviews: