  1. Safety Instructions   

 

 

WARNING   

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure 

that they also receive this instruction manual. 

Important: 
Damages  caused  by  the  disregard  of  this  user  manual  are  not  subject  to  warranty.  The 

dealer will not accept liability for any resulting defects or problems

—

 

Unpack and check carefully that there is no transportation damage before using the unit. 

—

 

The unit is for indoor use only. Use only in a dry location. 

—

 

Only to be installed and operated by qualified personnel. 

—

 

Do not allow children to operate the fixture. 

—

 

Use safety cables when installing the unit. Handle the unit by its base only. Do not carry with 

its head. 

—

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent 
surfaces.   

—

 

Be sure that no ventilation slots are blocked; otherwise the unit will overheated. 

—

 

Before operating, ensure that the voltage and frequency of power supply matches the power 

requirements of the unit. 

—

 

Always ground the yellow/green conductor to earth in order to avoid electric shock. 

—

 

Maximum ambient temperature TA: 40 . Don’t operate it when the temperature is higher. 

—

 

Do not connect the unit to a dimmer pack. 

—

 

Make sure there are no flammable materials close to the unit while operating.   

—

 

The  Unit’s  surface  temperature  may  reach  up  to  85 .  Do  not  touch  the  housing  with  bare 

hands  during  its  operation,  and  allow  about  15  minutes  for  the  unit  to  cool  down  before 

replacing the lamp or maintenance as it could be very hot. 

—

 

Avoid  any  inflammable  liquids,  water  or  metal  objects  entering  the  unit.  In  the  event  of  a 

problem cut off the mains power immediately. 

—

 

Do not operate in dirty or dusty environment; clean the unit regularly. 

—

 

Do not touch any power cables during operation as there may be a hazard of electric shock. 

—

 

The  minimum  distance  between  the  light  output  lens  and  the  illuminated  surface  must  be 

Please read carefully the instruction manual, which includes important 

information about installation, usage and maintenance. 

Summary of Contents for Beam 1RE

Page 1: ...Beam 1RE Order Code ELUM015 User Manual www prolight co uk ...

Page 2: ...n 5 3 1 Control Panel 5 4 How To Set The Unit 5 4 1 Main Functions 5 4 2 Home Position Adjustment 10 4 3 Error Information 11 5 Control By Universal DMX Controller 12 5 1 Connection 12 5 2 Address Setting 13 5 3 DMX 512 Configuration 13 6 Troubleshooting 16 7 Maintenance and Cleaning 17 ...

Page 3: ...that the voltage and frequency of power supply matches the power requirements of the unit Always ground the yellow green conductor to earth in order to avoid electric shock Maximum ambient temperature TA 40 Don t operate it when the temperature is higher Do not connect the unit to a dimmer pack Make sure there are no flammable materials close to the unit while operating The Unit s surface temperat...

Page 4: ...an lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed Disconnect the mains power if the fixture is not to be used for a long time Use the original packing materials before transporting the unit To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture Hot lamp explosion hazard Do not open the unit wit...

Page 5: ...ve Sound active LCD display One gobo wheel with 15 gobos plus open One colour wheel with 14 colours plus open 0 100 dimming and variable strobe speeds Voltage AC 100 240V 50 60Hz Power Consumption 190W LED OSRAM SIRIUS HRI 100W Beam Angle 3 Weight 9 2Kgs Dimension 387 x 284 x 255mm ...

Page 6: ...o connect to supply power 7 DMX In out 3 pin XLR connectors for DMX 512 operation 4 How To Set The Unit 4 1 Main Function Press the MENU button into menu mode press the UP and DOWN buttons until the required function is shown on the display Select the function by pressing the ENTER button Use the UP and DOWN buttons to choose the submenu press the ENTER button to store and automatically return to ...

Page 7: ...6A ...

Page 8: ...l or Slave 2 2 light show or Master mode Once the mode has been selected press the ENTER button to setup To go back to the functions without any changes press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode DMX State To select the DMX State press the ENTER button to show DMX STATE on the display Use the UP DOWN buttons to selec...

Page 9: ...press the ENTER button to show TILT INVERSE on the display Use the UP DOWN buttons to select Inverse tilt inversion or Normal normal mode Once the mode has been selected press the ENTER button to setup To go back to the functions without any changes press the MENU button again Press and hold the MENU button for about one second or wait for one minute to exit the menu mode Back Light To select the ...

Page 10: ...ode Lamp Power On To select the Lamp Power On press the ENTER button to show the LAMP POWER ON on the display Use the UP DOWN buttons to select the On Lamp on when power on or Off Lamp off when power off Once selected press the ENTER button to setup To go back to the functions without any changes press the MENU button again Press and hold the MENU button for about one second or wait for one minute...

Page 11: ...t To select the Pan Offset press the ENTER button to show PAN OFFSET on the display Use the UP and DOWN buttons to adjust the value from 127 to 127 press the ENTER button to store Press the MENU button to exit TILT OFFSET Tilt home position adjustment To select the Tilt Offset press the ENTER button to show TILT OFFSET on the display Use the UP and DOWN buttons to adjust the value from 127 to 127 ...

Page 12: ... show PRISM OFFSET on the display Use the UP and DOWN buttons to adjust the value from 0 to 255 press the ENTER button to store Press the MENU button to exit 4 3 Error Information Lamp Startup Fail It appears when there is no lamp fitted or the lamp has failed Temperature Sense Error It appears when temperature check board is damaged Lamp Too Hot Power Off It appears when the temperature is detect...

Page 13: ...ail Focus Reset fail They may appear when turning on or resetting the unit or when a PCB is damaged Please contact qualified maintenance 5 Control By Universal DMX Controller 5 1 Connection 1 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 2 Connect ...

Page 14: ...n4 Pin5 not used 5 2 Address Setting If you use a universal DMX controller to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press MENU button to enter the menu mode select DMX Functions and press the ENTER button to confirm Use the UP and DOWN buttons to select DMX Address press the ENTER button to confirm the present address will blink on the...

Page 15: ...pen Fast Open Slow Close Open Random Strobe Open 8 000 008 009 016 017 025 026 033 034 042 043 050 051 059 060 067 068 076 077 084 085 093 094 101 102 110 111 118 119 127 128 189 190 193 194 255 COLOR Open Colour1 Colour2 Colour3 Colour4 Colour5 Colour6 Colour7 Colour8 Colour9 Colour10 Colour11 Colour12 Colour13 Colour14 Rotation Fast Slow Stop Rotation Slow Fast 9 000 003 004 007 008 011 012 015 ...

Page 16: ...king Gobo10 Shaking Gobo11 Shaking Gobo12 Shaking Gobo13 Shaking Gobo14 Shaking Gobo15 Shaking Rotation Fast Slow Stop Rotation Slow Fast 10 000 007 008 255 PRISM No Effect Prism Effect 11 000 127 128 189 190 193 194 255 R PRISM Index 0 360 Rotation Fast Slow Stop Rotation Slow Fast 12 000 079 080 084 085 089 090 094 095 099 100 109 110 119 120 129 130 139 140 199 200 209 FUNCTION Null Pan Tilt Mo...

Page 17: ...e if it is illuminated B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors and cables to see if they are connected correctly 2 If the DMX LED is on and no response to the desk check the address settings and DMX polarity 3 Try another DMX controller 4 Check to see if the DMX cables run near or run alongside high voltage cables that may cause damage or interference ...

Page 18: ...ng frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth and use normal glass cleaner Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Page 19: ...in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Page 20: ...19A Innovation Quality Performance ...