Counting the operating hours with high voltage enabled in hh:mm:ss.
Showing the sparks resulting in the high voltage being disabled. If any of
the counters counts up to 6, an error spark 1 resp. 2 will be generated. If
no further sparks occur within 5 seconds, the counter will be reset.
Number of all sparks 1 which have occurred 1 or 2, also including the
sparks which have not resulted in the generator being disabled.
Counter of all sparks which have occurred.
List of the last 10 errors which have occurred. Scroll through the list using
the arrow keys.
no = running number
code = Error number
time = Time the error occurred as shown by the operating hour counter.
Capacity utilization of the internal micro-processor.
HV-hours
HV-hours
100:30:38
Sparks temporary
spark temporary
1: 3
2: 0
Sparks counter
spark counter
1: 123
2: 34
Error counter
error counter
8
Error list
no
code
time
1
8
5:15:32
P-utilization
P utilization
40.5 %